An asymmetrical dual coating on the stent prepared by ultrasonic atomization.

J Biomed Mater Res B Appl Biomater

Key Laboratory for Biorheological Science and Technology of Ministry of Education (Chongqing University), State and Local Joint Engineering Laboratory For Vascular Implants (Chongqing), Bioengineering College of Chongqing University, Chongqing, China.

Published: April 2019

This study aims to design an asymmetric dual coating (ADC) on the stent by ultrasonic atomization to solve the problem of delayed endothelialization and late or very late stent thrombosis which caused by drug eluting stent (DES) with symmetric coating. Chitosan-loaded monoclonal platelet glycoprotein IIIa receptor antibody SZ-21 coating (CSC) was sprayed on inner surface of stents, and outer surface was sprayed CSC and poly(lactic-co-glycolic acid) (PLGA) loaded with docetaxel (DTX) coating (PDC). The coated surface was uniform without aggregation and no shedding phenomenon either before or after stent expanded. Fluorescence labeling has confirmed that the coating has an asymmetric structure. The cumulative release for SZ-21 and DTX was 40.11% and 27.22% within first 24 h, then DTX became the major released drug from 24 h to 7 d, after released for 28 d about 40% of the SZ-21 and 50% DTX still remained on the coated stent. It achieved that ADC can inhibit thrombosis at earlier period and inhibit vascular smooth muscle cells (VSMCs) proliferation at later period. And that ADC has good hemocompatibility and can significantly inhibit VSMCs proliferation. Finally, 4 and 12 weeks after the stent with ADC implanted into rabbit carotid arteries, it showed that the stent with ADC was safe and could effectively prevent thrombosis and in-stent restenosis. © 2018 Wiley Periodicals, Inc. J. Biomed. Mater. Res. Part B, 2018. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 825-837, 2019.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.34179DOI Listing

Publication Analysis

Top Keywords

dual coating
8
stent
8
ultrasonic atomization
8
vsmcs proliferation
8
stent adc
8
2018 wiley
8
wiley periodicals
8
periodicals biomed
8
biomed mater
8
mater res
8

Similar Publications

The therapeutic effect of immune checkpoint inhibitors (ICIs) in triple-negative breast cancer (TNBC) is unsatisfactory. The immune "cold" microenvironment caused by tumor-associated fibroblasts (TAFs) has an adverse effect on the antitumor response. Therefore, in this study, mixed cell membrane-coated porous magnetic nanoparticles (PMNPs) were constructed to deliver salvianolic acid B (SAB) to induce an antitumor immune response, facilitating the transition from a "cold" to a "hot" tumor and ultimately enhancing the therapeutic efficacy of immune checkpoint inhibitors.

View Article and Find Full Text PDF

A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.

View Article and Find Full Text PDF

Background And Rationale: In-stent restenosis (ISR) remains the leading cause of treatment failure following percutaneous coronary intervention (PCI) with contemporary drug-eluting stents. Especially in small caliber coronary arteries, restenosis is common following PCI and represents a treatment challenge. Drug-coated balloons (DCB) are an attractive alternative to stents for treatment of both ISR and small vessel disease.

View Article and Find Full Text PDF

Acylase-Based Coatings on Sandblasted Polydimethylsiloxane-Based Materials for Antimicrobial Applications.

Polymers (Basel)

January 2025

Center for Micro-Electro Mechanical Systems (CMEMS), Campus Azurém, University of Minho, 4800-058 Guimarães, Portugal.

Indwelling medical devices, such as urinary catheters, often experience bacterial colonization, forming biofilms that resist antibiotics and the host's immune defenses through quorum sensing (QS), a chemical communication system. This study explores the development of antimicrobial coatings by immobilizing acylase, a quorum-quenching enzyme, on sandblasted polydimethylsiloxane (PDMS) surfaces. PDMS, commonly used in medical devices, was sandblasted to increase its surface roughness, enhancing acylase attachment.

View Article and Find Full Text PDF

The association between microRNAs and various diseases, especially cancer, has been established in recent years, indicating that miRNAs can potentially serve as biomarkers for these diseases. Determining miRNA concentrations in biological samples is crucial for disease diagnosis. Nevertheless, the stem-loop reverse transcription quantitative PCR method, the gold standard for detecting miRNA, has great challenges in terms of high costs and enzyme limitations when applied to clinical biological samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!