A comparison of tests for quantifying sensory eye dominance.

Vision Res

UCL Institute of Ophthalmology, University College London, Bath St, London EC1V 9EL, UK; School of Optometry and Vision Science, University of Auckland, Auckland 1142, New Zealand; New Zealand National Eye Centre, University of Auckland, Auckland 1142, New Zealand. Electronic address:

Published: December 2018

Clinicians rely heavily on stereoacuity to measure binocular visual function, but stereo-vision represents only one aspect of binocularity. Lab-based tests of sensory eye dominance (SED) are commonplace, but have not been translated to wider clinical practice. Here we compare several methods of quantifying SED in a format suitable for clinical use. We tested 30 participants with ostensibly normal vision on eight tests. Seven tests (#1-7) were designed to quantify SED in the form of an interocular balance-point (BP). In tests #1-6, we estimated a contrast-BP, the interocular difference in contrast required for observers to be equally likely to base their judgement on either eye, whereas in test #7 we measured binocular rivalry (interocular ratio of sensory dominance duration). We compare test-retest reliability (intra-observer consistency) and test-validity (inter-observer discriminatory power) and compare BP to stereoacuity (test #8). The test that best preserved inter-observer differences in contrast balance while maintaining good test-retest reliability was a polarity judgement using superimposed opposite-contrast polarity same-identity optotypes. A reliable and valid measure of SED can be obtained rapidly (20 trials) using a simple contrast-polarity judgement. Tests that use polarity-rivalrous stimuli elicit more reliable judgments than those that do not. SIGNIFICANCE STATEMENT: Although sensory eye dominance is central to understanding normal and disordered binocular vision, there is currently no consensus as to the best way to measure it. Here we compare several candidate measures of sensory eye dominance and conclude that a reliable measure of SED can be achieved rapidly using a judgement of stimulus contrast-polarity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.visres.2018.09.006DOI Listing

Publication Analysis

Top Keywords

sensory eye
16
eye dominance
16
test-retest reliability
8
measure sed
8
sensory
5
eye
5
dominance
5
tests
5
sed
5
comparison tests
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!