There are disadvantages in Elastic Stable Intramedullary Nailing (ESIN) of forearm-shaft fractures, such as the need of implant removal. Biodegradable Intramedullary Nailing (BIN) is a new technique developed for these fractures. We hypothesized that there is no difference in rotational ROM between the patients treated by BIN vs. ESIN. A randomized, controlled clinical trial included patients, aged 5-15 years, requiring surgery for forearm-shaft fractures. Biodegradable polylactide-co-glycolide (PLGA) nails (Activa IM-Nail™, Bioretec Ltd., Finland) were used in 19 and titanium nails (TEN, SynthesDePuy Ltd., USA) in 16 patients. Rotational ROM of forearm after two years was the primary outcome. Elbow and wrist ROM, pain and radiographic bone healing were secondary outcomes. Forearm rotation was mean 162° and 151° in BIN and ESIN groups, respectively (P = 0.201). No difference between the groups was found in any other ROMs. Three cases in the ESIN vs. none in the BIN group reported pain (P = 0.113). There was no clinically significant residual angulation in radiographs. Two adolescents in the BIN group vs. none in the ESIN (P = 0.245) were excluded because of implant failure; another two with complete bone union suffered from re-injury. Therefore, satisfactory implant stability among older children needs to be studied.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2018.09.011DOI Listing

Publication Analysis

Top Keywords

intramedullary nailing
12
fractures biodegradable
8
titanium nails
8
forearm-shaft fractures
8
rotational rom
8
bin esin
8
bin group
8
esin
5
bin
5
nailing forearm
4

Similar Publications

Introduction: Intramedullary tibial nailing is a standard treatment for tibial shaft fractures. Postoperative knee pain significantly impacts functional recovery; however, studies on this issue are limited. This study evaluated the effect of the parapatellar approach for intramedullary nailing on postoperative knee pain.

View Article and Find Full Text PDF

Background: Multiple approaches exist for operative fixation of metacarpal fractures; with common treatments including lag screw fixation or open-reduction internal fixation (ORIF) with plates and screws. Recently, the adaptation of intramedullary screw (IMS) placement has allowed for an essentially closed approach with stable fixation and theoretically improved outcomes. Thus, we sought to compare such approaches to ultimately determine the superior method for achieving the goal of return to normal function.

View Article and Find Full Text PDF

Purpose: Tibial open shaft fractures are very common and susceptible to infection, which can lead to significant morbidity especially infection and non-union. Antibiotic coated nail is one option for fixing open shaft tibial fractures to minimise infection. This study aimed to compare the clinical outcome of Gentamicin-coated tibial nails versus regular unreamed interlocking tibial nails in the treatment of type I and II tibial open fractures.

View Article and Find Full Text PDF

Carbon fibre reinforced polyetheretherketone (CFR-PEEK) implants have gained interest because of reported biomechanical advantages and radio-lucent properties. The aim of this study was to evaluate the role of CFR-PEEK nails in patients with metastatic bone disease (MBD). We performed a retrospective cohort study evaluating patients with MBD undergoing intramedullary (IM) nailing for prophylaxis or fixation of pathological fractures using CFR- PEEK or titanium implants.

View Article and Find Full Text PDF

Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.

View Article and Find Full Text PDF