A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implementation of a reformulated Roche® bilirubin Gen.3 reagent did not affect the relationship between BiliChek transcutaneous and Roche total serum bilirubin. | LitMetric

Objective: Determine whether introduction of a reformulated bilirubin reagent, the Roche bilirubin Gen.3 assay, changed the relationship between BiliChek transcutaneous bilirubin (TcB) and total serum bilirubin (TSB).

Design And Methods: TcB results from term infants in the level 1 nursery obtained within one hour of a TSB were reviewed over two periods, six months before and after the conversion from the previous generation Roche bilirubin reagent to the new Roche Gen.3 bilirubin assay. TcB measurements were performed using BiliChek transcutaneous devices (Respironics, Marietta GA). Distribution of TSB results, and TcB minus TSB bias, were compared before and after introduction of the reformulated Roche bilirubin Gen.3 assay. Median and interquartile range (IQR) TSB values and bias were calculated. A statistical difference between median TSB values and bias were assessed using Man-Whitney test.

Results: A total of 301 paired TcB and TSB results were obtained, 172 before and 129 after implementation of the reformulated Roche bilirubin Gen.3 reagent. Median (IQR) TSB was 7.8 (6.8-8.7)mg/dL (133.3 (116.3-148.8) μmol/L) before and 7.6 (6.7-8.4)mg/dL (130 (114.6-143.6)μmol/L) after implementation of the reformulated reagent (p = .1373). Median (IQR) bias between TcB and TSB was 2.9 (2.2-3.7) mg/dL (49.6 (37.6-63.3)μmol/L) before the reformulated reagent was implemented; and did not change at 2.9 (2.1-3.9) mg/dL (49.6 (35.9-66.7)μmol/L) after implementation (p = .8242).

Conclusion: Implementation of the reformulated Roche bilirubin Gen.3 reagent did not affect the relationship between BiliChek transcutaneous and total serum bilirubin; thus no changes were needed to the neonatal TcB screening protocol as a result of the new bilirubin reagent.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiochem.2018.10.001DOI Listing

Publication Analysis

Top Keywords

bilirubin gen3
20
roche bilirubin
20
implementation reformulated
16
bilichek transcutaneous
16
bilirubin
13
gen3 reagent
12
relationship bilichek
12
total serum
12
serum bilirubin
12
bilirubin reagent
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!