Objectives: To analyze the volumetric evolution of abdominal aortic aneurysms after endovascular sealing (EVAS) with the Nellix™ device during follow-up.
Methods: Patients who underwent elective EVAS in our institution in 2014 and 2015 were retrospectively reviewed. Preoperative, postoperative and 1-year scans were processed. A custom software was conceived to assess semi-automated measurements of the aneurysm sac and the endograft sizes including volume, maximum diameter, sectional area and perimeter. Thrombus volume, aneurysm length, mean distance between the stents inside the polymer-filled sacs and endograft migration were also estimated. Manual maximum diameters were measured for comparison. Inter and intra-observer variability of the proposed semi-automated method was evaluated.
Results: Pre-EVAS, post-EVAS and last follow-up scans of 12 patients were finally analyzed during a mean follow-up of 17 ± 5 months. No endograft migration or endoleak were detected. During follow-up, aneurysm volume and perimeter slightly increased compared to post-EVAS scans (+ 1 and + 5%, respectively, p < 0.05). A systematic 6% enlargement of the endobag volume was also observed (range 1-15 mL, p < 0.001). Endobag maximum diameter, area and perimeter increased 4, 8, and 8%, respectively (all p < 0.01). Mean plane-by-plane distance between stents increased 4% (p < 0.05). Mean thrombus volume did not change during follow-up, although a high variability was observed. Aneurysm and thrombus volume changes were highly correlated (r = 0.93, p < 0.001). No associations were observed between aneurysm and endobag volume changes. Intra- and inter-observer variability was below 1.7 and 2.4% for diameter and volume measurements, respectively. The automated measurements of post-EVAS aneurysm diameter and volume were higher than preoperative (p < 0.05). Maximum diameters measured manually did not differ between scans.
Conclusion: Small aneurysm volume enlargement detected during a mid-term follow-up was associated with thrombus size change, whereas systematic endograft expansion resulted independent from the aortic growth. Volumetric measurements using a semi-automated method could quantify small changes in aneurysm, endograft and thrombus sizes not detected by manually defined maximal diameters.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13239-018-00380-4 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.
The use of conventional contrast agents in computed tomography (CT) and magnetic resonance (MR) imaging is often limited in patients with chronic kidney disease (CKD) due to potential nephrotoxicity. Ferumoxytol, originally developed for iron supplementation, has emerged as a promising alternative MR contrast agent that is safer for patients with CKD. This study aims to present our center's experience with ferumoxytol as a contrast agent in CKD patients.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
April 2025
Division of Vascular and Endovascular Surgery, Department of Surgery, University of Texas Southwestern Medical Center, Dallas, TX.
Adverse iliofemoral anatomy represents a unique challenge for endovascular aortic aneurysm repair (EVAR). This report describes a transaxillary EVAR in a patient with severe iliofemoral occlusive disease and an infrarenal aortic aneurysm. A reversely mounted Gore Excluder graft was advanced and deployed in the infrarenal aorta using the left axillary artery.
View Article and Find Full Text PDFRen Fail
December 2025
Department of Nephrology, Chengyang District People's Hospital, Qingdao, China.
Background: Vascular calcification is common and progressive in patients with chronic kidney disease. However, the risk factors associated with the progression of vascular calcification in patients receiving maintenance dialysis have not been fully elucidated. Here, we aimed to evaluate vascular calcification and identify the factors associated with its progression in patients receiving maintenance hemodialysis.
View Article and Find Full Text PDFSci Rep
January 2025
Thoracic and Vascular Surgery Research Center, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran.
Abdominal Aortic Aneurysm (AAA) poses a significant health risk due to its silent nature and high mortality upon rupture. The Fib-4 index, initially designed for liver fibrosis assessment, presents potential beyond its scope. This study aims to investigate the association of FIB-4 with aneurysm size and mortality risk, exploring its utility as a risk predictor for enhanced clinical management.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Department of Surgery and Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
Objective: This study aimed to compare treatment outcomes between graft replacement and aneurysmorrhaphy with ligation of the aortic side branches for type 2 endoleaks after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms.
Methods: We retrospectively analyzed multicenter data of patients who underwent open surgical conversion, including graft replacement or aneurysmorrhaphy with ligation of the aortic side branches (graft preservation) for the treatment of type 2 endoleaks between 2007 and 2022. The endpoints were postoperative complications, 30-day mortality, overall survival, and reintervention or sac expansion after open surgical conversion.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!