Drinking water utilities currently rely on a range of microbiological detection techniques to evaluate the quality of their drinking water (DW). However, microbiota profiling using culture-free 16S rRNA gene next-generation sequencing (NGS) provides an opportunity for improved monitoring of the microbial ecology and quality of DW. Here, we evaluated the utility of a previously validated microbiota profiling platform (MYcrobiota) to investigate the microbial dynamics of a full-scale, non-chlorinated DW distribution system (DWDS). In contrast to conventional methods, we observed spatial and temporal bacterial genus changes (expressed as operational taxonomic units - OTUs) within the DWDS. Further, a small subset of bacterial OTUs dominated with abundances that shifted across the length of the DWDS, and were particularly affected by a post-disinfection step. We also found seasonal variation in OTUs within the DWDS and that many OTUs could not be identified, even though MYcrobiota is specifically designed to reduce potential PCR sequencing artefacts. This suggests that our current knowledge about the microbial ecology of DW communities is limited. Our findings demonstrate that the user-friendly MYcrobiota platform facilitates culture-free, standardized microbial dynamics monitoring and has the capacity to facilitate the introduction of microbiota profiling into the management of drinking water quality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6170421PMC
http://dx.doi.org/10.1038/s41598-018-32987-xDOI Listing

Publication Analysis

Top Keywords

drinking water
16
microbial dynamics
12
microbiota profiling
12
monitoring microbial
8
distribution system
8
user-friendly mycrobiota
8
mycrobiota platform
8
microbial ecology
8
otus dwds
8
drinking
4

Similar Publications

High Detection Rate of Rotavirus Infection Among Children Admitted with Acute Gastroenteritis to Six Public Hospitals in Luanda Province After the Introduction of Rotarix Vaccine: A Cross-Sectional Study.

Viruses

December 2024

Associate Laboratory for Animal and Veterinary Sciences (AL4AnimalS), Interdisciplinary Center for Research in Animal Health (CIISA), Faculty of Veterinary Medicine, University of Lisbon, 1300-477 Lisbon, Portugal.

Rotavirus group A (RVA) is a major cause of pediatric acute gastroenteritis (AGE). Vaccination is an effective public health strategy and Angola implemented it in 2014. This hospital-based study aimed to estimate the prevalence of RVA infection and the severity of AGE in children under five years of age treated at six hospitals in Luanda Province.

View Article and Find Full Text PDF

Groundwater is an essential drinking water source for humans. However, improper groundwater management leads to fecal contamination and waterborne diseases caused by viral pathogens. Therefore, this study aimed to investigate norovirus (NoV) contamination by conducting nationwide monitoring over five years (2019-2023).

View Article and Find Full Text PDF

The rapid development of the global chemical industry has led to widespread groundwater contamination, with frequent pollution incidents posing severe threats to water safety. However, there has been insufficient assessment of the health risks posed by chlorinated hydrocarbon contamination in groundwater around chemical industrial parks. This study evaluates the chlorinated hydrocarbon contamination in groundwater at a chemical park and conducts a multi-pathway health risk assessment, identifying the key risk pollutants.

View Article and Find Full Text PDF

Arsenic exposure can induce liver insulin resistance (IR) and diabetes (DM), but the underlying mechanisms are not yet clear. Circular RNAs (circRNAs) are involved in the regulation of the onset of diabetes, especially in the progression of IR. This study aimed to investigate the role of circRNAs in arsenic-induced hepatic IR and its underlying mechanism.

View Article and Find Full Text PDF

This study aimed to evaluate the annual pollution characteristics of trichloromethane (TCM) in Kunshan City's tap water from 2016 to 2022. This research analyzed 566 tap water samples from centralized water supply units, utilizing the GB 5749-2006 Sanitary Standard for Drinking Water as the evaluation benchmark. Data analysis employed non-parametric tests and Spearman's correlation analysis using Excel 2017 and SPSS 26.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!