Background: Recent studies have shown that medial branch radiofrequency neurotomy (RFN) procedures done at the level of a pedicle screw can increase pedicle screw temperature, and it has been speculated that pedicle screw heating may cause thermal injury. There has been a limited amount of investigation into the real-world safety profile of RFN procedures in patients with pedicle screws.

Objectives: We aim to demonstrate that the occurrence of serious adverse events is rare for a medial branch RFN procedure completed at a level with metallic spinal hardware when performed according to the Spine Intervention Society practice standards.

Study Design: This study involved retrospective chart reviews of every patient who received an RFN procedure for spinal facet joint pain during the 5-year time period from 2012-2016.

Setting: The research took place within a single university-based interventional pain management center.

Methods: The study sample included 507 patient charts. Data collection included patient demographics, RF denervation sites at a level with metallic hardware, and all serious RF-related complications that could be attributable to heated metallic hardware. The research team developed medical-chart abstraction criteria for each of the following categorized complications: a) superficial burns, b) deep burns, c) denervation of dorsal ramus, d) denervation of ventral ramus, and e) coagulation of a spinal vascular structure.

Results: Of the 36 patients who met the inclusion criteria for this study, 43.6% were men and 56.4% were women. The mean age was 59.5 years old, with an age range of 25 to 87 years. There were a total of 56 ablations performed at a level with metallic spinal hardware, of which 11 were cervical, 44 were lumbar, and 1 was thoracic . There were zero documented complications found among our patient population in any of the 5 categories of serious complications.

Limitations: As a retrospective chart review, this study was dependent on the availability and accuracy of medical records. Chart abstraction criteria for each outcome measure were developed by the research team without scientific testing.

Conclusions: There have been no reported complications attributable to hardware temperature increases when performing medial branch RFNs at the level of a pedicle screw. For safety, it is important to use multiplanar fluoroscopic imaging techniques to ensure that the RFN cannula is not in contact with the pedicle screw.

Key Words: Radiofrequency neurotomy, medial branch nerve ablation, safety, thermal injuries, metallic spinal hardware, pedicle screws, lateral mass screws, cervical facet joints, severe complications, adverse events.

Download full-text PDF

Source

Publication Analysis

Top Keywords

medial branch
16
pedicle screw
16
radiofrequency neurotomy
12
level metallic
12
metallic spinal
12
spinal hardware
12
procedures patients
8
rfn procedures
8
level pedicle
8
adverse events
8

Similar Publications

Purpose: The main objective of this study was to conduct a radioanatomical study of the osteo-myo-cutaneous scapulo-dorsal pedicled flap.

Methods: A radiological study was performed to study the anatomical variations of the dorsal scapular pedicle (origin, course of the deep branch of the dorsal scapular artery (DSA) in relation to the medial border of the scapula, perforators from the superficial branch of the DSA). Perforators from the superficial branch of the DSA were also identified on anatomical subjects, and their cutaneous vascular territory was determined.

View Article and Find Full Text PDF

Background: When patients with a failed hip arthroplasty are unsuitable for reimplantation, Girdlestone resection arthroplasty (GRA) is a viable treatment option. We report on a patient who was treated with a GRA due to a periprosthetic infection. We discovered partial paralysis of the quadriceps muscle in this patient.

View Article and Find Full Text PDF

Background: Innervation of the breast includes branches of thoracic intercostal nerves, the superficial cervical plexus, the brachial plexus, and the intercostobrachial nerve (ICBN). Commonly used blocks for breast surgery provide incomplete analgesia of the axillary region. This cadaveric study aims to identify and map the axillary sensory cutaneous nerves.

View Article and Find Full Text PDF

Introduction: Arterio-enteric fistula is one of the extremely rare complications of penetrating trauma.

Case Presentation: A 27-year-old male presented to the emergency department with a gunshot to the right buttock. Initial assessments revealed a left femoral shaft fracture, the right buttock as the bullet inlet and the medial portion of the left thigh as an outlet, with no other significant findings.

View Article and Find Full Text PDF

Purpose: The purpose of this case report is to present an anatomical variation of the radial artery observed in anatomical practice and to discuss its clinical significance.

Methods: During the dissection of the right upper limb of a Chinese adult male, a high-position variation of the right radial artery with the absence of the radial recurrent artery was found.

Results: The variant branch of the right radial artery originates from the brachial artery and arises medially in the upper one-third of the arm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!