A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Late rupture of artificial neochordae associated with hemolytic anemia. | LitMetric

A 63-year-old man, status post-mitral valve repair for severe mitral regurgitation secondary to ruptured chordae of the anterior leaflet, was admitted seven years after surgery because of a recent history of hematuria. A new apical pansystolic murmur was audible. Hemoglobin level was 5.7 g/dL. Results of other hematologic studies and a peripheral blood smear were indicative of mechanical hemolysis. Transesophageal echocardiography showed a high-velocity jet of mitral regurgitation that directly collided with the annuloplasty ring. At re-operation, one of the artificial neochordae to A2 and A3 segments was found to be disrupted. The mitral valve was replaced with a 33/31 mm On-X valve. Hemolytic anemia disappeared immediately after surgery. Although mitral valve repair with artificial neochodae has been shown to have long-term durability, it should be recognized that artificial neochordae may rupture a long time after mitral valve repair. Also, although hemolytic anemia is known as an early complication after mitral valve repair, it is worth knowing that hemolytic anemia may occur as a late complication after mitral valve repair. Continuous long-term monitoring of the patients after mitral valve repair is recommended. < Artificial neochordae may at times rupture long period after mitral valve repair. Also, although hemolytic anemia is known as an early complication after mitral valve repair, it may occur as a complication due to late rupture of artificial neochordae. Continuous long-term monitoring of the patient after mitral valve repair is recommended.>.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6149633PMC
http://dx.doi.org/10.1016/j.jccase.2017.06.007DOI Listing

Publication Analysis

Top Keywords

valve repair
36
mitral valve
36
artificial neochordae
20
hemolytic anemia
20
complication mitral
12
valve
11
mitral
11
repair
9
late rupture
8
rupture artificial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!