Static and dynamic calibration of torsional spring constants of cantilevers.

Rev Sci Instrum

Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8, Canada.

Published: September 2018

A method for calibrating the dynamic torsional spring constant of cantilevers by directly measuring the thermally driven motion of the cantilever with an interferometer is presented. Random errors in calibration were made negligible (<1%) by averaging over multiple measurements. The errors in accuracy of ±5% or ±10% for both of the cantilevers calibrated in this study were limited only by the accuracy of the laser Doppler vibrometer (LDV) used to measure thermal fluctuations. This is a significant improvement over commonly used methods that result in large and untraceable errors resulting from assumptions made about the cantilever geometry, material properties, and/or hydrodynamic physics of the surroundings. Subsequently, the static torsional spring constant is determined from its dynamic counterpart after careful LDV measurements of the torsional mode shape, backed by finite element analysis simulations. A meticulously calibrated cantilever is used in a friction force microscopy experiment that measures the friction difference and interfacial shear strength (ISS) between graphene and a silicon dioxide AFM probe. Accurate calibration can resolve discrepancies between different experimental methods, which have contributed to a large scatter in the reported friction and ISS values in the literature to date.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5045679DOI Listing

Publication Analysis

Top Keywords

torsional spring
8
static dynamic
4
dynamic calibration
4
calibration torsional
4
spring constants
4
constants cantilevers
4
cantilevers method
4
method calibrating
4
calibrating dynamic
4
dynamic torsional
4

Similar Publications

A Novel Dynamic Growth Rod Inducing Spinal Growth Modulation for the Correction of Spinal Deformities.

JOR Spine

March 2025

Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable & Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering Beihang University Beijing China.

Background: Growth rods are the gold standard for treating early-onset scoliosis (EOS). However, current treatments with growth rods do not optimize spinal growth in EOS patients, and frequent distraction surgeries significantly increase complications, imposing considerable economic and psychological burdens on patients. An improved growth rod is urgently required to address the need for dynamic growth and external regulation.

View Article and Find Full Text PDF

A Whole-Body Coordinated Motion Control Method for Highly Redundant Degrees of Freedom Mobile Humanoid Robots.

Biomimetics (Basel)

December 2024

School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China.

Humanoid robots are becoming a global research focus. Due to the limitations of bipedal walking technology, mobile humanoid robots equipped with a wheeled chassis and dual arms have emerged as the most suitable configuration for performing complex tasks in factory or home environments. To address the high redundancy issue arising from the wheeled chassis and dual-arm design of mobile humanoid robots, this study proposes a whole-body coordinated motion control algorithm based on arm potential energy optimization.

View Article and Find Full Text PDF

Testicular cancer is one of the leading malignancies affecting young men, with germ cell tumors (GCTs) being the most prevalent type. These tumors are classified into two main subtypes: seminomas and non-seminomatous germ cell tumors (NSGCTs), with the latter known for their higher likelihood of metastasis. Early detection through imaging and tumor markers like alpha-fetoprotein (AFP) and beta-human chorionic gonadotropin (HCG) is crucial for favorable outcomes.

View Article and Find Full Text PDF

The study presents a new configuration of nonlinear energy sinks (NESs) which is adaptable to function as either stable or bistable NES. The proposed NES is based on the spring-loaded inverted pendulum (SLIP) in which a torsional stiffness element couples the SLIP to the linear oscillator (LO). The bistable configuration provides a critically stable position when the SLIP is vertically aligned with respect to the LO motion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!