A quasi-coaxial high-voltage (HV) rolled pulse forming line (rolled PFL) is researched in this paper. The PFL is rolled circles on a support cylinder simultaneously by two layers of copper foil electrodes and two layers of insulation dielectrics. The first circle of the two electrodes are elicited in opposite directions along the axis, acting as the quasi-coaxial output structure of the PFL, and the left n - 1 circles of the PFL form a complete rolled strip line of n - 1 circles. The rolled PFL is convenient to realize HV insulation and is able to output a pulse with good quality. Characteristic parameters of the PFL are designed theoretically. Besides, the pulse discharge process of the PFL is simulated by computer simulation technology (CST) modeling, and the simulation result verifies the correctness of theory design. Furthermore, a rolled PFL with a characteristic impedance of 4.4 Ω is developed. The test characteristic impedance of the developed PFL by the incident pulse method confirms to the theory design. The discharge voltage waveform with a full width at half maximum of 57 ns of the PFL is acquired, which has a rise time of 6.8 ns. The HV test of the rolled PFL is carried out, and a discharge current pulse with an amplitude of 7 kA is acquired when the PFL is charged to 70 kV. It is calculated that the developed PFL has an energy storage density of 2.5 J/l. A Tesla generator based on 13 stages of rolled PFLs is designed, which is expected to output a 450 kV pulse with a duration of 100 ns on a 40-Ω match load. The discharge waveform of the generator is simulated by the CST software. The simulative output pulse has a rise time of 5 ns, with a flattop jitter less than 5%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5030133 | DOI Listing |
Rev Sci Instrum
September 2018
Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, P.O. Box 69 Branch 13, Xi'an 710024, China.
A quasi-coaxial high-voltage (HV) rolled pulse forming line (rolled PFL) is researched in this paper. The PFL is rolled circles on a support cylinder simultaneously by two layers of copper foil electrodes and two layers of insulation dielectrics. The first circle of the two electrodes are elicited in opposite directions along the axis, acting as the quasi-coaxial output structure of the PFL, and the left n - 1 circles of the PFL form a complete rolled strip line of n - 1 circles.
View Article and Find Full Text PDFPlant Physiol
July 2011
Biotechnology Research Institute/National Key Facility for Genetic Resources and Gene Improvement, Chinese Academy of Agricultural Sciences, Beijing 100081, People's Republic of China.
Leaf rolling is considered an important agronomic trait in rice (Oryza sativa) breeding. To understand the molecular mechanism controlling leaf rolling, we screened a rice T-DNA insertion population and isolated the outcurved leaf1 (oul1) mutant showing abaxial leaf rolling. The phenotypes were caused by knockout of Rice outermost cell-specific gene5 (Roc5), an ortholog of the Arabidopsis (Arabidopsis thaliana) homeodomain leucine zipper class IV gene GLABRA2.
View Article and Find Full Text PDFRev Sci Instrum
April 2010
College of Photoelectrical Science and Engineering, National University of Defense Technology, Changsha 410073, People's Republic of China.
An all solid-state and compact pulsed strip pulse forming line (PFL) is investigated both theoretically and experimentally. The electromagnetic field distribution and the pulse formation in the strip PFL are analyzed numerically. Based on the theoretical analysis and numerical results, a rolled strip PFL with output voltage of 20 kV, pulse duration of 230 ns, and characteristic impedance of 0.
View Article and Find Full Text PDFPlasmid
May 2004
Department of Food Science and Microbiology, University of Milan, Via Celoria 2, 20133, Italy.
The complete nucleotide sequences of two plasmids, pFL5 and pFL7, isolated from soil bacteria, Bacillus licheniformis FL5 and FL7, have been determined. The plasmids pFL5 and pFL7 were analyzed and found to be 9150 and 7853 bp in size with a G+C content of 41.0 and 43.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!