A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usefulness of six-minute walk test in systemic sclerosis. | LitMetric

The 6-minute walk test (6MWT) is a standardised, feasible and reliable measure of sub-maximal exercise capacity that has never been fully validated in systemic sclerosis (SSc). A variety of data suggest that many non-pulmonary aspects of SSc contribute to the test results, thus blunting the ability of the 6MWT to measure changes in lung function. Sources of variability are a training effect, technician experience, subject encouragement, medication, other activities on day of testing, deconditioning and the effects of musculoskeletal conditions and pain. Another cause of variability is the anatomical site the probe is attached to: a forehead probe is preferable to a finger or earlobe sensor. The indiscriminate use of the 6MWT for all SSc patients is not useful. It should be used in patients with pulmonary involvement, combined with diffusion capacity of the lung for carbon monoxide (DLCO) and its components (membrane diffusion and capillary volume) or the Sclerodermia Health Assessment Questionnaire Disability Index. The use of these combined parameters may indicate the onset of pulmonary hypertension. Recent studies suggest two alternatives to the 6MWT: maximal cardiopulmonary exercise testing and DLCO testing during effort. However, their use must still be validated.

Download full-text PDF

Source

Publication Analysis

Top Keywords

walk test
8
systemic sclerosis
8
six-minute walk
4
test systemic
4
sclerosis 6-minute
4
6-minute walk
4
6mwt
4
test 6mwt
4
6mwt standardised
4
standardised feasible
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!