Dynamic nuclear polarization (DNP) can increase nuclear magnetic resonance (NMR) signal strengths by factors of 100 or more at low temperatures. In magnetic resonance imaging (MRI), signal enhancements from DNP potentially lead to enhancements in image resolution. However, the paramagnetic dopants required for DNP also reduce nuclear spin relaxation times, producing signal losses that may cancel the signal enhancements from DNP. Here we investigate the dependence of H NMR relaxation times, including T and T, under conditions of Lee-Goldburg H-H decoupling and pulsed spin locking, on temperature and dopant concentration in frozen solutions that contain the trinitroxide compound DOTOPA. We find that relaxation times become longer at temperatures below 10 K, where DOTOPA electron spins become strongly polarized at equilibrium in a 9.39 T magnetic field. We show that the dependences of relaxation times on temperature and DOTOPA concentration can be reproduced qualitatively (although not quantitatively) by detailed simulations of magnetic field fluctuations due to flip-flop transitions in a system of dipole-coupled electron spin magnetic moments. These results have implications for ongoing attempts to reach submicron resolution in inductively detected MRI at very low temperatures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6465147PMC
http://dx.doi.org/10.1021/acs.jpcb.8b07958DOI Listing

Publication Analysis

Top Keywords

relaxation times
16
magnetic resonance
12
nuclear spin
8
spin relaxation
8
paramagnetic dopants
8
resonance imaging
8
low temperatures
8
signal enhancements
8
enhancements dnp
8
magnetic field
8

Similar Publications

This research explores the types and effectiveness of occlusal splints in managing temporomandibular disorders (TMDs). TMDs encompass a range of musculoskeletal and neuromuscular conditions affecting the jaw, causing pain, limited movement, and discomfort. Occlusal splints, also known as bite guards, are commonly used in dentistry to alleviate TMD symptoms by relaxing jaw muscles, preventing joint trauma, and protecting teeth.

View Article and Find Full Text PDF

Introduction: We previously demonstrated efficacy of an 8-antigen recombinant subunit vaccine against a single species homologous challenge in lambs and in lambing ewes in pen trials. We subsequently demonstrated efficacy of a simplified, 2-antigen, version of this vaccine in lambs in pen trials. Here, we test both vaccines in lambing ewes in a field setting.

View Article and Find Full Text PDF

Tsunamis are massive waves generated by sudden water displacement on the ocean surface, causing devastation as they sweep across the coastlines, posing a global threat. The aftermath of the 2004 Indian Ocean tsunami led to the establishment of the Indian Tsunami Early Warning System (ITEWS). Predicting real-time tsunami heights and the resulting coastal inundation is crucial in ITEWS to safeguard the coastal communities.

View Article and Find Full Text PDF

Introduction: Some targets of relational peer victimization become depressed because of their poor treatment. These associations are well documented in youth but are rarely studied in adults.

Methods: The longitudinal pathways between relational peer victimization (being excluded, stonewalled, etc.

View Article and Find Full Text PDF

Compact high-bandwidth single-beam optically-pumped magnetometer for biomagnetic measurement.

Biomed Opt Express

January 2025

State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China.

Optically-pumped magnetometer (OPM) has been of increasing interest for biomagnetic measurements due to its low cost and portability compared with superconducting quantum interference devices (SQUID). Miniaturized spin-exchange-relaxation-free (SERF) OPMs typically have limited bandwidth (less than a few hundred Hertz), making it difficult to measure high-frequency biomagnetic signals such as the magnetocardiography (MCG) signal of the mouse. Existing experiments mainly use SQUID systems to measure the signal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!