Investigation of genotoxic and apoptotic effects of zirconium oxide nanoparticles (20 nm) on L929 mouse fibroblast cell line.

Chem Biol Interact

Department of Biotechnology, Faculty of Science and Letters, Mersin University, Mersin, Turkey.

Published: December 2018

In recent years, advances in nano-scale technology have led to the use of nanoparticles in almost all areas of life. Nanoparticles (NP) have been acknowledged as one of the emerging environmental threats; however, studies in different components of environment are limited. Among the available nanoparticles, zirconium oxide nanoparticles are widely used in tooth coating and cosmetic products. In this study, three different concentrations of 20 nM Zirconium Oxide nanoparticles were used to investigate the genotoxic and apoptotic effects in vitro conditions by single cell gel electrophoresis (Comet) and flow cytometry methods on L929 Mouse Fibroblast cell line. In this study, we aimed to decipher whether Zirconium Oxide nanoparticles had genotoxic and apoptotic effects on fibroblast cells or not. The relationship between the apoptotic effect and the genotoxic effect was examined. Three different concentrations (50 μg/ml, 100 μg/ml and 150 μg/ml) of 20 nM Zirconium Oxide nanoparticles were used on L929 cells in order to determine the relationship between apoptotic and genotoxic parameters. Our results support that Zirconium Oxide nanoparticles induced DNA damage and apoptosis at all used concentrations. In vivo studies are currently conducted to further evaluate the cytotoxic effect of these nanoparticles.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cbi.2018.09.017DOI Listing

Publication Analysis

Top Keywords

zirconium oxide
24
oxide nanoparticles
24
genotoxic apoptotic
12
apoptotic effects
12
nanoparticles
10
l929 mouse
8
mouse fibroblast
8
fibroblast cell
8
three concentrations
8
20 nm zirconium
8

Similar Publications

In laser safety eyewear, due to the lack of complete blocking of ultraviolet and infrared rays, we proposed a structure based on one-dimensional multilayer composed of several layers of silicon dioxide and zirconium dioxide materials alternately behind polycarbonate lens. It is find out that the acceptance angle range to the photonic crystal is 0 to 39°. This incident angle range corresponds to the band gap of the photonic crystal.

View Article and Find Full Text PDF

Comparison of Ceramic Bonding to Cobalt-Chromium, Zirconia and Nickel-Chromium Alloys Fabricated Using of Various Techniques.

J Biomed Mater Res B Appl Biomater

January 2025

Dental Materials Unit, Center for Dental Medicine, Clinic for Masticatory Disorders and Dental Biomaterials, University of Zurich, Zurich, Switzerland.

The purpose of this study was to evaluate the characteristics of the ceramic bonding to cobalt-chromium (Co-Cr) alloys fabricated by casting, milling, and additive manufacturing, compared with zirconia and nickel-chromium. One hundred specimens (N = 100), prepared with the dimensions of 25 × 3 × 0.5 mm, were assigned to five groups (n = 20): presintered milled Co-Cr (Group M), additively manufactured Co-Cr (Group SLM), cast Co-Cr (Group C), presintered zirconia (Group Zi), and cast Ni-Cr (Group Ni).

View Article and Find Full Text PDF

Background: Conservative dentistry introduced modern restoration designs, contributing to the greater use of partial-coverage ceramic restorations. New strong bondable ceramic materials made fabricating partial coverage ceramic restorations easier to restore the badly destructed teeth.

Aim Of The Study: This study investigated the impact of three distinct overlay preparation designs on the marginal fit (both before and after thermal aging) and the fracture resistance of overlay restorations fabricated using advanced zirconia-reinforced lithium disilicate (ALD) CAD/CAM glass-ceramic blocks.

View Article and Find Full Text PDF

Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.

Settings And Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.

Materials And Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone.

View Article and Find Full Text PDF

Background: Although surface finishing processes are effective against Streptococcus mutans biofilm, the mechanism of action of saliva with different acidity values ​​has not been studied in detail. This study aims to produce four different all-ceramic materials in a single session with CAD/CAM devices and apply two different surface finishing processes, glazing and polishing, and then determine the retention of Streptococcus mutants on the surfaces of the materials in saliva with varying levels of acidity.

Methods: Zirconia-reinforced lithium silicate (Vita Suprinity, Vita Zahnfabrik, Bad Saöckingen, Germany), monochromatic feldspar (Vitablocs Mark 2, Vita Zahnfabrik, Bad Saöckingen, Germany), leucite glass ceramic (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein), and monolithic zirconia (Incoris TZI (Cerec) Sirona, Germany) were used in the study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!