Background: Native aortic coarctation in young infants can be treated surgically or with balloon angioplasty, although the latter approach remains controversial. We sought to compare midterm outcomes of balloon and surgical coarctoplasty at our center and to review the current practices in literature.

Methods: The study design was a retrospective record review. Patients with coarctation aged <1 year who underwent balloon or surgical coarctoplasty at our center (January 2010-January 2016) with >6-month post-procedure follow-up were studied. Patients with significant arch hypoplasia or interruption, long-segment coarctation, and associated intracardiac lesions were excluded from the study. Clinical, echocardiographic, and procedural details were recorded at initial presentation and follow-up. Need for reintervention was noted.

Results: Out of a total of 75 patients, 28 underwent balloon (Group A) and 47 underwent surgical coarctoplasty (Group B). There were two deaths in Group B (mortality 4.2%) and none in Group A. In neonates, 63.6% of Group A and 17.4% of Group B patients required reintervention ( = 0.007). Beyond the neonatal age, 29.4% of Group A and 41.6% of Group B patients required reintervention (not statistically significant). On univariate analysis, residual coarctation on predischarge echocardiogram was the only significant predictor of reintervention ( = 0.04). On Kaplan-Meier analysis, with neonatal presentation, freedom from reintervention in Group B was significantly higher than Group A ( = 0.028).

Conclusion: In neonates with native aortic coarctation, surgery unequivocally yields better immediate and midterm results and is the preferred treatment modality. In older infants, balloon coarctoplasty has good early and midterm outcomes with acceptable reintervention rates and should be considered a viable alternative to surgery, especially in critical patients with high surgical risk.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6146845PMC
http://dx.doi.org/10.4103/apc.APC_165_17DOI Listing

Publication Analysis

Top Keywords

native aortic
12
aortic coarctation
12
midterm outcomes
12
group
10
outcomes balloon
8
balloon angioplasty
8
surgical coarctoplasty
8
group patients
8
patients required
8
required reintervention
8

Similar Publications

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF

According to current guidelines, patients with heart valve disease should be followed by Heart Valve Clinics (HVCs). Regular quality analysis is a major prerequisite of an HVC's program, but few data have been reported so far. We retrospectively collected patients with isolated, native aortic valve stenosis who had been visited in our HVC at least once between 2021 and 2024.

View Article and Find Full Text PDF

Single-Stage Surgical Approach to Aortoesophageal Fistula After Thoracic Endovascular Aortic Repair.

Ann Thorac Surg Short Rep

September 2024

Department of Cardiovascular Surgery, Xiangya Hospital, Central South University, Changsha, Hunan, China.

Background: The aortoesophageal fistula (AEF) caused by thoracic endovascular aortic repair is a challenging condition. Traditional treatment approaches have been associated with high mortality and morbidity. This study introduces a modified single-stage surgical strategy that aims to optimize outcomes and to reduce the risk of recurrence for AEF.

View Article and Find Full Text PDF

Objective: The study objective was to investigate the effect of free-edge length on valve performance in bicuspidization repair of congenitally diseased aortic valves.

Methods: In addition to a constructed unicuspid aortic valve disease model, 3 representative groups-free-edge length to aortic diameter ratio 1.2, 1.

View Article and Find Full Text PDF

Background: Valve-related haemolysis is a known complication following prosthetic valve surgery. Haemolysis after transcatheter aortic valve implantation (TAVI) has been reported in some studies, all of which were non-critical. Data related to haemolysis associated with new-generation balloon-expandable valve (BEV) are scarce.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!