Background And Aims: Clinical data suggest that the quality of optical diagnoses of colorectal polyps differs markedly among endoscopists. The aim of this study was to develop a computer program that was able to differentiate neoplastic from non-neoplastic polyps using unmagnified endoscopic pictures.

Methods: During colonoscopy procedures polyp photographies were performed using the unmagnified high-definition white light and narrow band image mode. All detected polyps (n = 275) were resected and sent to pathology. Histopathological diagnoses served as the ground truth. Machine learning was used in order to generate a computer-assisted optical biopsy (CAOB) approach. In the test phase pictures were presented to CAOB in order to obtain optical diagnoses. Altogether 788 pictures were available (602 for training the machine learning algorithm and 186 for CAOB testing). All test pictures were also presented to two experts in optical polyp characterization. The primary endpoint of the study was the accuracy of CAOB diagnoses in the test phase.

Results: A total of 100 polyps (of these 52% neoplastic) were used in the CAOB test phase. The mean size of test polyps was 4 mm. Accuracy of the CAOB approach was 78.0%. Sensitivity and negative predictive value were 92.3% and 88.2%, respectively. Accuracy obtained by two expert endoscopists was 84.0% and 77.0%. Regarding accuracy of optical diagnoses CAOB predictions did not differ significantly compared to experts (p = .307 and p = 1.000, respectively).

Conclusions: CAOB showed good accuracy on the basis of unmagnified endoscopic pictures. Performance of CAOB predictions did not differ significantly from experts' decisions. The concept of computer assistance for colorectal polyp characterization needs to evolve towards a real-time application prior of being used in a broader set-up.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00365521.2018.1501092DOI Listing

Publication Analysis

Top Keywords

optical diagnoses
12
caob
9
colorectal polyps
8
unmagnified endoscopic
8
machine learning
8
caob approach
8
test phase
8
pictures presented
8
polyp characterization
8
accuracy caob
8

Similar Publications

Purpose: This study evaluated the efficacy, safety, and tolerability of a single-dose, preservative-free (PF) Dorzolamide/Timolol combination (Twinzol-SDU).

Methods: A 3-month single-arm, multicenter, prospective cohort study was conducted in Egypt between January 2021 and October 2022 on previously diagnosed and controlled patients with ocular hypertension and/or glaucoma. Efficacy was assessed using the change in intraocular pressure (IOP) after 6 and 12 weeks.

View Article and Find Full Text PDF

L-ICG as an optical agent to improve intraoperative margin detection in breast-conserving surgery: a prospective study.

Breast Cancer Res Treat

January 2025

Diagnosis and Treatment Center of Breast Diseases, Shantou Central Hospital, Waima Road 114, Jinping District, Shantou, 515041, China.

Purpose: Precise tumor excision is important in breast-conserving surgery (BCS). This study explores the safety and accuracy of fluorescence image-guided BCS (FIGS) using a lidocaine mucilage-ICG compound (L-ICG).

Methods: 54 patients who underwent BCS from August 2020 to September 2023 were enrolled.

View Article and Find Full Text PDF

High dose aflibercept treatment in naive neovascular age-related macular degeneration.

Int Ophthalmol

January 2025

Beyoglu Eye Training and Research Hospital, University of Health Sciences, Bereketzade Camii Sk. No:2 Beyoğlu, 34421, Istanbul, Turkey.

Background: To evaluate the efficacy and safety of intravitreal injections of 4 mg (high dose) of aflibercept in treatment-naive patients with neovascular AMD(nAMD) with treat and extend(TREX) dosing regimens, and to determine the frequency of injections.

Methods: In this interventional, retrospective study a total of 15 eyes of 14 patients (eight female and 9 male) with nAMD were included. All patients were examined and OCT imaging was performed at the time of initial presentation, on the day of each injection and at subsequent follow-up visits.

View Article and Find Full Text PDF

Purpose: To determine whether corneal biomechanical parameters can predict ectasia progression.

Study Design: Retrospective observational study.

Methods: The baseline corneal biomechanical parameters of 64 eyes of 41 young patients (age, < 25 years at the first visit) who were diagnosed with keratoconus (KC) or suspected KC at Osaka University Hospital and followed up for more than two years were reviewed.

View Article and Find Full Text PDF

Factors associated with the time of glaucoma-related adverse events onset after pediatric cataract surgery and the preferred anti-glaucomatous surgical selection.

Int Ophthalmol

January 2025

Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, 83 Fenyang Road, Shanghai, 200031, China.

Purpose: To describe the clinical characteristics of glaucoma-related adverse events (GRAE) after pediatric cataract surgery. More importantly, to identify the factors associated with the time of GRAE onset and the preferred anti-glaucomatous surgical procedure for this disease.

Methods: Hospitalized medical records of patients who developed GRAE, which include glaucoma and glaucoma suspect, after pediatric cataract surgery (surgical age ≤ 14 years) between 1994 and 2021 were retrospectively reviewed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!