Despite the growing evidence with emerging transcatheter tricuspid valve repair therapies, the experience with transcatheter tricuspid valve replacement remains sparse. We describe a case of severe tricuspid regurgitation in a 79-year-old patient deemed unsuitable for isolated tricuspid valve surgery, successfully treated with a 40-mm self-expandable NaviGate (NaviGate Cardiac Structures, Inc, Lake Forest, CA) valved stent via a transatrial approach, with excellent result and hemodynamic performance at 4 months.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2018.07.481DOI Listing

Publication Analysis

Top Keywords

tricuspid valve
16
transcatheter tricuspid
12
valve replacement
8
severe tricuspid
8
tricuspid regurgitation
8
tricuspid
5
valve
4
replacement treating
4
treating severe
4
regurgitation initial
4

Similar Publications

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF

Aims: Pulmonary regurgitation (PR) after reparative intervention for congenital heart disease has been studied extensively. However, the burden, distribution of causes, and outcome of PR in adults is unknown. The study aimed to evaluate the prevalence, types, and outcomes of moderate/severe PR in adults in the community setting.

View Article and Find Full Text PDF

Background: Undergoing an urgent valve surgical procedure to treat patients with tricuspid valve endocarditis carries a high risk of operative morbidity and mortality. Use of a percutaneous vacuum-assisted system to treat tricuspid valve endocarditis is an alternative to surgical procedures.

Methods: This study retrospectively analyzed data from 187 transcatheter vacuum-assisted aspiration procedures performed in 177 patients with tricuspid valve vegetations at 3 different centers between 2017 and April 2022.

View Article and Find Full Text PDF

Background: The rate of permanent pacemaker implantation after tricuspid valve (TV) operation is thought to be high, with some studies quoting rates of 20% to 30%. We identified the rate of pacemaker implantation after TV operation at a high-volume regional reference center to better characterize the contemporary risk of pacemaker.

Methods: All adult patients without preexisting pacemakers undergoing TV operation from 2011 to 2022 were included.

View Article and Find Full Text PDF