A new diclofenac molecularly imprinted electrochemical sensor based upon a polyaniline/reduced graphene oxide nano-composite.

Biosens Bioelectron

Phase Equilibria Research Laboratory, Department of Chemistry, Faculty of Science, The University of Zanjan, Postal Code 45371-38791 Zanjan, Iran.

Published: December 2018

AI Article Synopsis

  • A diclofenac-imprinted polymer was created using a combination of polyaniline, reduced graphene oxide, and triphenylamine to produce a selective electrochemical sensor for detecting diclofenac.
  • The sensor’s effectiveness was examined through cyclic voltammetry, revealing a clear anodic peak at around 0.5 V, and a calibration curve indicated a linear response for diclofenac concentrations between 5-80 mg/L.
  • The sensor demonstrated a low detection limit of 1.1 mg/L and high precision, with relative standard deviations of 2.43% and 2.47% for inter- and intra-day analyses, respectively, making it suitable for DCF detection in various solutions, including pharmaceutical

Article Abstract

A diclofenac (DCF)-imprinted polymer, composed of polyaniline, reduced graphene oxide (rGO) and triphenylamine, as cross linker, was synthetized. This composite was identified by using SEM and FT-IR techniques. The prepared DCF-imprinted polymer (MIP) was used for modification of carbon paste electrodes (CPEs) to fabricate a selective DCF electrochemical sensor. Electrochemical behavior of DCF on the investigated sensor and the optimization of the parameters affecting the DCF determination were screened by cyclic voltammetry (CV). The cyclic voltammogram of DCF showed an anodic peak current at about 0.5 V (vs. SCE). The calibration curve for DCF determination was obtained by applying the investigated sensor as working electrode in differential pulse voltammetry (DPV). A linear increase in the anodic peak current was observed in the range 5-80 mg L of DCF. The corresponding limit of detection was calculated to be 1.1 mg L. The relative standard deviations of the inter- and intra-day analysis of DCF presented by the method were found to be as 2.43% and 2.47%, respectively. The selectivity of the investigated sensor was evaluated by its use for determination of DCF in the binary solutions containing DCF/glucose, DCF/urea and DCF/ascorbic acid. It was shown that the fabricated electrode can be successfully used for analysis of DCF in pharmaceutical and urine samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2018.09.047DOI Listing

Publication Analysis

Top Keywords

investigated sensor
12
dcf
9
electrochemical sensor
8
graphene oxide
8
dcf-imprinted polymer
8
dcf determination
8
anodic peak
8
peak current
8
analysis dcf
8
sensor
5

Similar Publications

Extremal structures with embedded prefailure indicators.

Proc Natl Acad Sci U S A

February 2025

Department of Construction Sciences, Lund University, Lund SE-22100, Sweden.

Preemptive identification of potential failure under loading of engineering structures is a critical challenge. Our study presents an innovative approach to design built-in prefailure indicators within multiscale structural designs with optimized load carrying capabilities utilizing the design freedom of topology optimization. The indicators are engineered to visibly signal load conditions approaching the global critical buckling load at predefined locations.

View Article and Find Full Text PDF

Investigating Smartphone-Based Sensing Features for Depression Severity Prediction: Observation Study.

J Med Internet Res

January 2025

Department of Clinical Psychology and Psychotherapy, Institute of Psychology and Education, Ulm University, Ulm, Germany.

Background: Unobtrusively collected objective sensor data from everyday devices like smartphones provide a novel paradigm to infer mental health symptoms. This process, called smart sensing, allows a fine-grained assessment of various features (eg, time spent at home based on the GPS sensor). Based on its prevalence and impact, depression is a promising target for smart sensing.

View Article and Find Full Text PDF

Purpose In recent years, research on caregivers has highlighted the importance of integrating advanced technologies, such as wearable devices. Furthermore, when investigating the characteristics of persons with dementia (PWD), comparative analyses should be conducted based on the presence or absence of the condition. We aimed to elucidate the relationship between caregivers' subjective burdens, tasks, and heart rate (HR) using wearable sensors to objectively assess the health status of caregivers of PWD and older adults requiring long-term care.

View Article and Find Full Text PDF

Acetone is harmful to the environment and human health. Therefore, research on acetone sensors for its high-efficiency detection is necessary. Herein, an α-FeO-TiO-MXene heterojunction was synthesized using a simple precipitation method, and its sensitivity towards acetone was systematically investigated.

View Article and Find Full Text PDF

Introduction: The novel object test is one of the three most common fear tests in veterinary science and employed in several different species. Although having been applied in several different studies in horses, it is surprising that there is no standardized test procedure available for these kinds of tests.

Methods: This study investigated the performance of the novel object test on 42 young Thoroughbred horses to determine the effect of sex (mare or stallion), test sites (round pen or paddock) and whether the horses had previously participated in an auction or not on the behavior during the novel object test.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!