A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly Sensitive and Flexible Strain-Pressure Sensors with Cracked Paddy-Shaped MoS/Graphene Foam/Ecoflex Hybrid Nanostructures. | LitMetric

Three-dimensional graphene porous networks (GPNs) have received considerable attention as a nanomaterial for wearable touch sensor applications because of their outstanding electrical conductivity and mechanical stability. Herein, we demonstrate a strain-pressure sensor with high sensitivity and durability by combining molybdenum disulfide (MoS) and Ecoflex with a GPN. The planar sheets of MoS bonded to the GPN were conformally arranged with a cracked paddy shape, and the MoS nanoflakes were formed on the planar sheet. The size and density of the MoS nanoflakes were gradually increased by raising the concentration of (NH)MoS. We found that this conformal nanostructure of MoS on the GPN surface can produce improved resistance variation against external strain and pressure. Consequently, our MoS/GPN/Ecoflex sensors exhibited noticeably improved sensitivity compared to previously reported GPN/polydimethylsiloxane sensors in a pressure test because of the existence of the conformal planar sheet of MoS. In particular, the MoS/GPN/Ecoflex sensor showed a high sensitivity of 6.06 kPa at a (NH)MoS content of 1.25 wt %. At the same time, it displayed excellent durability even under repeated loading-unloading pressure and bending over 4000 cycles. When the sensor was attached on a human temple and neck, it worked correctly as a drowsiness detector in response to motion signals such as neck bending and eye blinking. Finally, a 3 × 3 tactile sensor array showed precise touch sensing capability with complete isolation of electrodes from each other for application to touch electronic applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.8b11233DOI Listing

Publication Analysis

Top Keywords

sensor high
8
high sensitivity
8
mos nanoflakes
8
planar sheet
8
mos
6
sensor
5
highly sensitive
4
sensitive flexible
4
flexible strain-pressure
4
strain-pressure sensors
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!