Purpose: To measure the arterial input function (AIF), an essential component of tracer kinetic analysis, in a population of patients using an optimized dynamic contrast-enhanced (DCE) imaging sequence and to estimate inter- and intrapatient variability. From these data, a representative AIF that may be used for realistic simulation studies can be extracted.

Methods: Thirty-nine female patients were imaged on multiple visits before and during a course of neoadjuvant chemotherapy for breast cancer. A total of 97 T -weighted DCE studies were analyzed including bookend estimates of T and model-fitting to each individual AIF. Area under the curve and cardiac output were estimated from each first pass peak, and these data were used to assess inter- and intrapatient variability of the AIF.

Results: Interpatient variability exceeded intrapatient variability of the AIF. There was no change in cardiac output as a function of MR visit (mean value 5.6 ± 1.1 L/min) but baseline blood T increased significantly following the start of chemotherapy (which was accompanied by a decrease in hematocrit).

Conclusion: The AIF in an individual patient can be measured reproducibly but the variability of AIFs between patients suggests that use of a population AIF will decrease the precision of tracer kinetic analysis performed in cross-patient comparison studies. A representative AIF is presented that is typical of the population but retains the characteristics of an individually measured AIF.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.27524DOI Listing

Publication Analysis

Top Keywords

intrapatient variability
12
arterial input
8
input function
8
aif
8
tracer kinetic
8
kinetic analysis
8
inter- intrapatient
8
representative aif
8
cardiac output
8
variability
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!