A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of manual pulse palpation, cardiac ultrasonography and Doppler ultrasonography to check the pulse in cardiopulmonary arrest patients. | LitMetric

Objective: For health professionals, the absence of pulse checked by manual palpation is a primary indicator for initiating chest compressions in patients considered to have cardiopulmonary arrest (CA). However, using a pulse check to evaluate perfusion during CA may be associated with some risks of its own. Our objective was to compare the efficiency of cardiac ultrasonography (CUSG), Doppler ultrasonography (DUSG), and manual pulse palpation methods to check the pulse in CA patients.

Material And Methods: This study was prospectively performed in 137 patients older than 16 years of age who underwent cardiopulmonary resuscitation (CPR). CUSG, DUSG, and manual pulse palpation were practiced simultaneously as suggested in the relevant guidelines. Findings of the patients were recorded at the first min, at min 15 and at the end of CPR. SPSS 18.0 was used for statistical analysis.

Findings: A total of 72.3% (n = 99) of the cardiopulmonary arrest incidents occurred out-of-hospital. CUSG (4.76 ± 2.19, 4.33 ± 2.17, and 3.68 ± 2.14 s), DUSG (9.59 ± 2.37, 8.22 ± 2.86, and 7.60 ± 2.83 s), and manual pulse palpation (10.76 ± 1.03, 9.72 ± 3.01, and 9.29 ± 3.36 s) measurements of the first, second, and last inspections were detected, respectively. The false negative rates (100%, 28%, and 0%) and false positive rates (5.3%, 3.5%, and 0%) of manual pulse palpation the first, second, and last inspections were calculated, respectively, as well.

Conclusion: The use of real-time CUSG during resuscitation provides a substantial contribution to the resuscitation team. CUSG will allow earlier and more accurate detection of pulse than manual pulse palpation and DUSG.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resuscitation.2018.09.018DOI Listing

Publication Analysis

Top Keywords

manual pulse
24
pulse palpation
24
cardiopulmonary arrest
12
pulse
11
cardiac ultrasonography
8
doppler ultrasonography
8
check pulse
8
dusg manual
8
second inspections
8
palpation
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!