A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New three-dimensional/four-dimensional volume rendering imaging software for detecting the abnormally invasive placenta. | LitMetric

Objective: This study aimed to determine the role of three-dimensional (3D)/four-dimensional (4D) volume rendering ultrasound (VRU) in the diagnosis of abnormally invasive placenta (AIP).

Materials And Methods: Twelve consecutive patients strongly suspected of having AIP on the basis of conventional ultrasound (US) and clinical history performed between September 2016 and December 2016 in the main tertiary referral hospital in Surabaya, East Java were included in this prospective observational study. A Samsung WS 80A Elite US scanner with a 3D/4D "crystal vue" and "realistic vue" volume rendering mode was used to establish the diagnosis of AIP and evaluate the site, and depth of placental invasion. The VRU images were compared with the intraoperative findings.

Results: Using this novel US technique, all cases of suspected AIP were subsequently confirmed during surgery. Importantly, the new US technique provided a correct diagnosis of the degree of invasion in 11 out of these 12 suspected AIP cases: 5/5 for placenta percreta, 3/3 for placenta increta, and 2/3 for placenta accreta; one patient was misdiagnosed in terms of the degree of placenta accreta, and one patient had normal implantation).

Conclusion: This new software of 3D/4D VRU represents a promising technique for the preoperative diagnosis and staging of AIP.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jcu.22641DOI Listing

Publication Analysis

Top Keywords

volume rendering
12
suspected aip
12
abnormally invasive
8
invasive placenta
8
placenta accreta
8
accreta patient
8
placenta
6
aip
5
three-dimensional/four-dimensional volume
4
rendering imaging
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!