An Online First version of this article was made available online at http://link.springer.com/journal/40263/onlineFirst/page/1 on 24 August 2018. An error was subsequently identified in the article, and the following correction should be noted.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6828358 | PMC |
http://dx.doi.org/10.1007/s40263-018-0574-9 | DOI Listing |
Transl Vis Sci Technol
January 2025
Department of Ophthalmology, University Hospital Bonn, Bonn, Germany.
Purpose: To compare a novel high-resolution optical coherence tomography (OCT) with improved axial resolution (High-Res OCT) with conventional spectral-domain OCT (SD-OCT) with regard to their capacity to characterize the disorganization of the retinal inner layers (DRIL) in diabetic maculopathy.
Methods: Diabetic patients underwent multimodal retinal imaging (SD-OCT, High-Res OCT, and color fundus photography). Best-corrected visual acuity and diabetes characteristics were recorded.
Prehosp Emerg Care
January 2025
Department of Emergency Medicine, University of Michigan Medical School, Ann Arbor, Michigan.
Objectives: Out-of-hospital cardiac arrest (OHCA) victims receiving defibrillation from an automated external defibrillator (AED) placed early in the chain of survival are more likely to survive. We sought to explore the accuracy of AED pad placement for lay rescuers (LR) and first responders (FR).
Methods: We conducted a secondary analysis of data collected during randomized OHCA simulation trials involving LRs and FRs.
J Acoust Soc Am
January 2025
Grundfos A/S, Bjerringbro, 8550, Denmark.
In this paper, an improved version of the classical equivalent radiated power (ERP) approximation is proposed based on principled physical arguments. A geometry-, frequency-, and vibration pattern-dependent approximation of radiation efficiency is developed and used as a corrective factor for the classical ERP approximation. The proposed method called "radiation efficiency varying equivalent radiated power" (revERP), is shown to greatly improve the accuracy of classical ERP at low Helmholtz numbers, while attaining the accuracy of classical ERP at high Helmholtz numbers.
View Article and Find Full Text PDFSimul Healthc
January 2025
From the Department of Human Factors (H.S., Y.P., E.T., L.D.W.), Center for the Simulation, Research, and Patient Safety, Carilion Clinic, Roanoke, VA; and Health Systems and Implementation Science (S.H.P.), Virginia Tech Carilion School of Medicine, Roanoke, VA.
Introduction: Virtual Monitor Technicians (VMTs) are crucial in remotely monitoring inpatient telemetry. However, little is known about VMT workload and intratask performance changes, and their potential impact on patient safety. This exploratory study used a high-fidelity simulation aimed to evaluate VMTs' workload and performance changes over time in telemetry monitoring and identify future research directions for performance improvement.
View Article and Find Full Text PDFCrit Rev Anal Chem
January 2025
College of Electrical Engineering, Naval University of Engineering, Wuhan, P.R. China.
Laser-induced breakdown spectroscopy (LIBS) technology has been widely used in many fields including industrial production, space exploration, medical analysis, environmental pollution detection, etc. However, the stability problem of LIBS is one of the core problems for its further development. Solutions in the LIBS field in recent decades were summarized and classified from the physical mechanism and analysis method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!