Background: Using the film model method, the process whereby a substance called tendon gel is secreted from transected tendon ends and changed into a tendon after application of a traction force is known. The objective of this study was to investigate the association between mechanical properties in the early stages of tendon regeneration and time by using the film model method.

Method: Adult male ddY mice, closed colony mice established and maintained in Japan, were prepared for each experimental group. The study animals were 30 mice and were divided into three groups of 10 mice each. Ten specimens of tendon gel secreted from the transected tendon ends were collected on days 10, 15, and 20 postoperatively. While a traction force of 0.00245 N was applied to these specimens, the process of tendon gel changing into a tendon was video recorded for 24 h, and the length of extension was measured over time. Regenerated tendons were stained with hematoxylin and eosin for histological examination. Healing site was studied histologically according to the our maturity score with reference to the Bonar's scale.

Results: The day 10 specimens gradually stretched for 12 h after the start of pulling and transformed into tendons. In contrast, the day 15 and 20 specimens stretched immediately after the start of pulling and transformed into tendons. The day 10 specimens stretched significantly more than the day 15 and 20 specimens (mechanical strain; 0.43 ± 0.26%, 0.03 ± 0.02%, and 0.03 ± 0.01%, respectively)Statistically significant differences were observed in the day 10 specimens than in the day 15 and 20 specimens. (P < 0.017). Using our maturity scores, the day 15 and 20 specimens were more mature than the day 10 specimens. (1.6 ± 0.68, 3.9 ± 0.54, and 4.8 ± 0.64, respectively) Statistically significant differences were observed in the day 10 specimens than in the day 15 and 20 specimens (P < 0.017).

Conclusion: Tendon gel physiologically and histologically matures on or after day 15 and becomes stronger dynamically in mechanical strength after day 15 than after day 10.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6150864PMC
http://dx.doi.org/10.1186/s40634-018-0152-6DOI Listing

Publication Analysis

Top Keywords

day specimens
24
tendon gel
12
regenerated tendons
8
film model
8
tendon
8
gel secreted
8
secreted transected
8
transected tendon
8
tendon ends
8
traction force
8

Similar Publications

The fish intestine is a complex ecosystem where microbial communities are dynamic and influenced by various factors. Preservation conditions during field collection can introduce biases affecting the microbiota amplified during sequencing. Therefore, establishing effective, standardized methods for sampling fish intestinal microbiota is crucial.

View Article and Find Full Text PDF

Introduction: While cadaveric dissections remain the cornerstone of education in skull base surgery, they are associated with high costs, difficulty acquiring specimens, and a lack of pathology in anatomical samples. This study evaluated the impact of a hand-crafted three-dimensional (3D)-printed head model and virtual reality (VR) in enhancing skull base surgery training.

Research Question: How effective are 3D-printed models and VR in enhancing training in skull base surgery?

Materials And Methods: A two-day skull base training course was conducted with 12 neurosurgical trainees and 11 faculty members.

View Article and Find Full Text PDF

Background & Aims: The developmental origin of health and disease hypothesis shows that early adverse exposures can have lifelong health effects. Thus, the aim of this study was to analyze the impact of choline intake during pregnancy and/or lactation on gene expression profiles in the liver of 24-day-old male rat offspring from dams with non-alcoholic fatty liver disease (NAFLD).

Methods: Phenotypic characteristic, histological examination and global transcriptome pattern of liver tissue specimens obtained from offspring of dams suffering from fatty liver, provided with proper choline intake during pregnancy and lactation (NN), fed a choline-deficient diet during both periods (DD), deprived of choline only during pregnancy (DN), or only during lactation (ND), was performed.

View Article and Find Full Text PDF

Background: The study evaluated the safety and adequacy of percutaneous transsternal anterior mediastinal core biopsy.

Methods: All percutaneous computed tomography-guided transsternal mediastinal 18-gauge core biopsies performed at 2 academic centers were retrospectively reviewed. Procedural, clinical, and pathology data were recorded.

View Article and Find Full Text PDF

Subject-specific finite element models of knee joint contact mechanics are used in assessment of interventions and disease states. Cartilage thickness distribution is one factor influencing the distribution of pressure. Precision of cartilage geometry capture varies between imaging protocols.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!