Adapting the chemical unfolding assay for high-throughput protein screening using experimental and spectroscopic corrections.

Anal Biochem

Just Biotherapeutics, Inc., 401 Terry Ave N., Seattle, WA, 98109, USA. Electronic address:

Published: December 2018

The chemical unfolding (denaturation) assay can be used to calculate the change in the Gibbs free energy of unfolding, ΔG, and inflection point of unfolding, to collectively inform on molecule stability. Here, we evaluated methods for calculating the ΔG across 23 monoclonal antibody sequence variants. These methods are based on how the measured output (intrinsic fluorescence intensity) is treated, including utilizing (a) a single wavelength, (b) a ratio of two wavelengths, (c) a ratio of a single wavelength to an area, and (d) a scatter correction plus a ratio of a single wavelength to an area. When applied to the variants, the three ratio methods showed comparable results, with a similar pooled standard deviation for the ΔG calculation, while the single-wavelength method is shown as inadequate for the data in this study. However, when light scattering is introduced to simulated data, only the scatter-correction area normalization method proves robust. Using this method, common plate-based spectrophotometers found in many laboratories can be used for high-throughput screening of mAb variants and formulation stability studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6226613PMC
http://dx.doi.org/10.1016/j.ab.2018.08.027DOI Listing

Publication Analysis

Top Keywords

single wavelength
12
chemical unfolding
8
ratio single
8
wavelength area
8
adapting chemical
4
unfolding
4
unfolding assay
4
assay high-throughput
4
high-throughput protein
4
protein screening
4

Similar Publications

Free-Space to SMF Integration and Green to C-Band Conversion Based on PPLN.

Sensors (Basel)

December 2024

Graduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.

In this study, we experimentally demonstrate a PPLN-based free-space to SMF (single-mode fiber) conversion system capable of efficient long-wavelength down-conversion from 518 nm, optimized for minimal loss in highly turbid water, to 1540 nm, which is ideal for low-loss transmission in standard SMF. Leveraging the nonlinear optical properties of periodically poled lithium niobate (PPLN), we achieve a wavelength conversion efficiency of 1.6% through difference frequency generation while maintaining a received optical signal-to-noise ratio of 10.

View Article and Find Full Text PDF

We demonstrate high-resolution single-pixel imaging (SPI) in the visible and near-infrared wavelength ranges using an SPI framework that incorporates a novel, dedicated sampling scheme and a reconstruction algorithm optimized for the rapid imaging of highly sparse scenes at the native digital micromirror device (DMD) resolution of 1024 × 768. The reconstruction algorithm consists of two stages. In the first stage, the vector of SPI measurements is multiplied by the generalized inverse of the measurement matrix.

View Article and Find Full Text PDF

This paper presents a lens-free imaging approach utilizing an array of light sources, capable of measuring the dielectric properties of many particles simultaneously. This method employs coplanar electrodes to induce velocity changes in flowing particles through dielectrophoretic forces, allowing the inference of individual particle properties from differential velocity changes. Both positive and negative forces are detectable.

View Article and Find Full Text PDF

This study introduces a novel deposition technique capable of depositing thin films with any arbitrary thickness profile. The apparatus consists of a fixed shadow mask and a rotating sample carrier plate. The shadow mask features a specifically designed opening curve that corresponds to the particular thickness profile of the deposited film.

View Article and Find Full Text PDF

Lighting the Path: Raman Spectroscopy's Journey Through the Microbial Maze.

Molecules

December 2024

Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4, 07743 Jena, Germany.

The rapid and precise identification of microorganisms is essential in environmental science, pharmaceuticals, food safety, and medical diagnostics. Raman spectroscopy, valued for its ability to provide detailed chemical and structural information, has gained significant traction in these fields, especially with the adoption of various excitation wavelengths and tailored optical setups. The choice of wavelength and setup in Raman spectroscopy is influenced by factors such as applicability, cost, and whether bulk or single-cell analysis is performed, each impacting sensitivity and specificity in bacterial detection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!