Introduction: There is a lack of in vivo studies comparing the functional outcome and knee stability after anterior cruciate ligament reconstruction (ACLR) using fixed loop (EndoButton (EB) CL) and adjustable loop (TightRope (TR) RT) devices for femoral fixation of soft tissue grafts.

Materials And Methods: Functional outcomes were assessed in terms of the International Knee Documentation Committee (IKDC) and Lysholm scores, knee stability by anteroposterior laxity and side-to-side difference (SSD) using KT-1000 arthrometer. The evaluation was performed preoperatively and post-operatively at 6 months and 2 years.

Results: Both groups were matched in terms of demographic, preoperative, intraoperative and post-operative covariates. EB ( n = 52) appeared to have better IKDC and Lysholm scores at 6 months post-operative when compared to TR ( n = 50). However, at a final follow-up of 2 years, the results were similar. The anterior tibial translation and SSD were statistically insignificant between the two groups at 6 months and 2 years.

Conclusion: ACLR using EB or TR for femoral fixation gives substantially equivalent functional results and knee stability at mid-term follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1177/2309499018799787DOI Listing

Publication Analysis

Top Keywords

femoral fixation
12
knee stability
12
fixed loop
8
loop endobutton
8
endobutton adjustable
8
adjustable loop
8
loop tightrope
8
ikdc lysholm
8
lysholm scores
8
vivo comparison
4

Similar Publications

Association Between Nail Type and Aseptic Revision Risk After Cephalomedullary Nailing for Hip Fracture.

J Bone Joint Surg Am

January 2025

Surgical Outcomes and Analysis Department, Kaiser Permanente, San Diego, California.

Background: Although the majority of intertrochanteric femoral fractures in the United States are now treated with cephalomedullary nailing, it remains uncertain whether differences in clinical performance by nail type exist. The purpose of this study was to compare the aseptic revision rates associated with the 3 most commonly utilized cephalomedullary nails in the United States today: the Gamma nail (Stryker), the INTERTAN (Smith+Nephew), and the Trochanteric Fixation Nail/Trochanteric Fixation Nail Advanced (TFN/TFNA; DePuy Synthes).

Methods: Using an integrated health-care system's hip fracture registry, patients ≥60 years of age who were treated with 1 of these 3 commonly used cephalomedullary nail devices were identified.

View Article and Find Full Text PDF

Background: While there have been significant advancements in recent years, complications following fixation for femoral neck fractures remain a concern. This retrospective cohort study aimed to investigate the influence of polytrauma and additional fractures on the occurrence of complications in patients who underwent surgical fixation for femoral neck fractures. The study focused on analyzing patient demographics, comorbidities, fracture classifications, fixation methods, and the likelihood of experiencing post-operative complications, with a specific emphasis on the impact of polytrauma and additional fractures.

View Article and Find Full Text PDF

The aim was to study the independent risk factors of internal fixation failure in proximal femoral anti-rotation intramedullary nailing for intertrochanteric femur fracture, and to build a nomogram prediction model accordingly. Clinical data of patients with intertrochanteric femoral rotor fractures admitted to the First People's Hospital of Longquanyi District from January 2018 to January 2023 were retrospectively collected. The occurrence of spiral blade cut out, internal fixation breakage, peri-internal fixation fracture, hip internal rotation deformity, and fracture nonunion within 1 year after surgery were included in the internal fixation failure group, and the rest were included in the internal fixation success group.

View Article and Find Full Text PDF

As surgeons, we strive to recognize and correct any mistakes that may occur before completing an operation, and importantly, do our best to avoid irreversible mistakes. Over-resection of the femoral cam lesion in patients having hip arthroscopy for femoroacetabular impingement syndrome has been considered irreversible. While cam under-resection is a technical complication of femoroacetabular impingement surgery to be avoided, avoiding this at the expense of over-resection of the proximal femur is of great concern.

View Article and Find Full Text PDF

Use of Cemented Hemiarthroplasty for Femoral Neck Fractures.

J Am Acad Orthop Surg Glob Res Rev

January 2025

From the Department of Orthopaedics, University of Missouri-Kansas City, Kansas City, MO (Dr. Amin, Dr. Krumme, Dr. Gause, Dr. Dubin, and Dr. Cil), and the Department of Orthopaedics, Kansas City Orthopaedic Alliance, Leawood, KS (Dr. Krumme).

Geriatric femoral neck fractures are common orthopaedic injuries, which are associated with a high morbidity and mortality. Arthroplasty is the optimum treatment for many of these injuries, but debate exists regarding optimal surgical strategy. Multiple recent investigations have demonstrated strong superiority for cemented stems as compared with noncemented fixation with a decreased risk of periprosthetic fracture, shorter length of stay, lower cost, and decreased rate for revision surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!