Campylobacter causes an estimated 1.3 million diarrheal illnesses in the United States annually (1). In August 2017, the Florida Department of Health notified CDC of six Campylobacter jejuni infections linked to company A, a national pet store chain based in Ohio. CDC examined whole-genome sequencing (WGS) data and identified six isolates from company A puppies in Florida that were highly related to an isolate from a company A customer in Ohio. This information prompted a multistate investigation by local and state health and agriculture departments and CDC to identify the outbreak source and prevent additional illness. Health officials from six states visited pet stores to collect puppy fecal samples, antibiotic records, and traceback information. Nationally, 118 persons, including 29 pet store employees, in 18 states were identified with illness onset during January 5, 2016-February 4, 2018. In total, six pet store companies were linked to the outbreak. Outbreak isolates were resistant by antibiotic susceptibility testing to all antibiotics commonly used to treat Campylobacter infections, including macrolides and quinolones. Store record reviews revealed that among 149 investigated puppies, 142 (95%) received one or more courses of antibiotics, raising concern that antibiotic use might have led to development of resistance. Public health authorities issued infection prevention recommendations to affected pet stores and recommendations for testing puppies to veterinarians. This outbreak demonstrates that puppies can be a source of multidrug-resistant Campylobacter infections in humans, warranting a closer look at antimicrobial use in the commercial dog industry.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6147421 | PMC |
http://dx.doi.org/10.15585/mmwr.mm6737a3 | DOI Listing |
Cureus
December 2024
Department of Emergency and Intensive Care Medicine, Hospital of the University of Occupational and Environmental Health, Fukuoka, JPN.
Objectives The objective of this study was to evaluate the occupational radiation exposure of healthcare workers during positron emission tomography (PET)/CT examinations, focusing on patient positioning and assessing the effectiveness of different radiation protection measures. Methods Thirteen medical workers (physicians, radiological technologists, and nurses) performed PET/CT examinations on 86 patients at a major Japanese hospital from June to August 2019. Occupational doses were measured using a real-time semiconductor dosimeter: RaySafe i2 (Unfors RaySafe, Billdal, Sweden), recording the 1 cm dose equivalent (Hp(10)).
View Article and Find Full Text PDFBMC Public Health
December 2024
Center for Agriculture and Food Security and Preparedness, Department of Biomedical and Diagnostic Sciences, College of Veterinary Medicine, University of Tennessee, Knoxville, USA.
Food Res Int
November 2024
Department of Biological Systems Engineering, Washington State University, P.O. Box-646120, WA 99164-6120, USA. Electronic address:
Pressure-assisted thermal sterilization (PATS) utilizes flexible packaging with low oxygen and water vapor transmission rates (OTRs, WVTRs). In this study, pouches made from metal oxide (MO)-coated (A-D) and ethylene vinyl alcohol (EVOH)-containing (E, F) multilayer films were filled with water and mashed potatoes (MP), preheated at 98 ± 0.5 °C for 10 min, and processed using a pilot-scale high-pressure processing machine (HPP) at 600 ± 5 MPa for 300 s.
View Article and Find Full Text PDFPhys Chem Chem Phys
December 2024
Yerevan State University, Yerevan 0025, Armenia.
Metalized-film dielectric capacitors provide lump portions of energy on demand. While the capacities of various capacitor designs are comparable in magnitude, their stabilities make a difference. Dielectric breakdowns - micro-discharges - routinely occur in capacitors due to the inevitable presence of localized structure defects.
View Article and Find Full Text PDFJ Hazard Mater
December 2024
Analytical Chemistry Group, Department of Plant and Environmental Science, University of Copenhagen, Thorvaldsensvej 40, Frederiksberg C 1871, Denmark.
Estimating the chemical hazards of drinking water stored in reusable plastic bottles is challenging due to the numerous intentionally and unintentionally added chemicals. To address this, we developed a broad screening strategy using evaporation enrichment and liquid chromatography high-resolution mass spectrometry (LC-HRMS) to evaluate migration of non-volatile chemicals from various reusable plastic bottles. The study analyzed a wide range of materials, revealing significant variability in chemical profiles across different bottle types.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!