A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Muscle Activation During Power-Oriented Resistance Training: Continuous vs. Cluster Set Configurations. | LitMetric

Morales-Artacho, AJ, García-Ramos, A, Pérez-Castilla, A, Padial, P, Gomez, AM, Peinado, AM, Pérez-Córdoba, JL, and Feriche, B. Muscle activation during power-oriented resistance training: continuous vs. cluster set configurations. J Strength Cond Res 33(7S): S95-S102, 2019-This study examined performance and electromyography (EMG) changes during a power training protocol comprising continuous or clustered set configurations. Eighteen active males completed 6 sets of 6 repetitions during the loaded (20% 1 repetition maximum) countermovement jump (CMJ) exercise, continuously (n = 9) or with a 30-second pause every 2 repetitions (cluster; n = 9). Power output, vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) EMG were recorded during all CMJs. Relative changes from the first repetition were assessed on the EMG root mean square (RMS), median frequency (Fmed), and a low- to high-frequency ratio index of fatigue (FInsmk). Greater power output decrements were observed during the continuous set configuration (p = 0.001, (Equation is included in full-text article.)< 0.01). Greater RMS increments in VL (6.8 ± 11.3 vs. -1.7 ± 5.8%) and RF (9.3 ± 14.2 vs. 1.9 ± 6.9%), but not VM (2.0 ± 4.7 vs. 2.6 ± 7.3%), were also observed in the continuous compared with the cluster sets (p = 0.033, (Equation is included in full-text article.)= 0.06). Progressive decrements in Fmed and increments in FInsmk were observed across repetitions in both set configurations. In conclusion, although clustering sets between repetitions clearly maintained power output, mixed responses were observed on the examined EMG parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000002811DOI Listing

Publication Analysis

Top Keywords

set configurations
16
power output
12
muscle activation
8
activation power-oriented
8
power-oriented resistance
8
resistance training
8
training continuous
8
continuous cluster
8
cluster set
8
sets repetitions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!