A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microfluidic thread-based electrode system to detect glucose and acetylthiocholine. | LitMetric

A reusable and simple to fabricate electrochemical sensor for the detection of glucose and acetylthiocholine using thread-based electrodes and nylon thread is described. The fabrication of the device consisted of two steps. First, three nylon-based electrodes (reference, working, and counter) were painted with one layer of conductive inks (silver and carbon ink, or silver/silver chloride ink). The electrodes were taped onto parafilm, and a piece of white nylon thread was wrapped around each electrode connecting the three electrodes. For the glucose system, a PBS solution containing glucose oxidase (GOx) (10 mg/mL), and potassium ferricyanide (K [Fe(CN) ]) (10 mg/mL) as mediator, was dried onto the thread, and increasing concentrations of glucose (0-15 mM) was added to the thread and measured by cyclic voltammetry (CV). The current output from the glucose oxidation was proportional to the concentration of glucose. For the second system, a solution of acetylcholinesterase (AChE) (0.08 U/mL) in PBS was added to the nylon thread, and increasing concentrations of acetylthiocholine (ATC) (0-9.84 mg/mL) was added and measured by CV. The current output from the oxidation of thiocholine (produced by AChE reacting with ATC) was proportional to the concentrations of ATC added to the thread. From both systems, a graph of current output versus substrate concentration was produced and fitted with a linear regression line that gave R values of 0.985 (GO /glucose) and 0.995 (AChE/ATC).

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201800348DOI Listing

Publication Analysis

Top Keywords

nylon thread
12
current output
12
glucose acetylthiocholine
8
thread increasing
8
increasing concentrations
8
glucose
7
thread
6
microfluidic thread-based
4
thread-based electrode
4
electrode system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!