Improved methods for MRI-compatible implants in nonhuman primates.

J Neurosci Methods

Institute of Neuroscience, Henry Welcome Building, Medical School, Framlington Place, Newcastle upon Tyne, NE2 4HH, United Kingdom. Electronic address:

Published: October 2018

Background: Neuroscientists commonly use permanently implanted headposts to stabilize the head of nonhuman primates (NHPs) during electrophysiology and functional magnetic resonance imaging (fMRI). Here, we present improved methodology for MRI-compatible implants without the use of acrylic for head stabilization in NHPs.

New Method: MRI is used to obtain a 3D-reconstruction of NHP skulls, which are used to create customized implants by modeling intersections with the bone. Implants are manufactured from PEEK using computer numerical control machining and coated with hydroxyapatite to promote osseointegration. Surgically, implants are attached to the skull with ceramic screws, while the skin flap is pulled over the implant and closed subcutaneously.

Results: Quality of blood oxygen level dependent (BOLD) fMRI signal is improved in animals implanted with our method as compared to traditional acrylic implants. Additionally, implants are well-integrated with the skull, remain robust for more than a year and without granulation tissue around the skin margin.

Comparison With Existing Method(s): Previous improvements on NHP implants (Chen et al., 2017; McAndrew et al., 2012; Mulliken et al., 2015; Overton et al., 2017) lacked fMRI-compatibility, as they relied on titanium headposts and/or titanium screws. Thus, most fMRI studies in NHPs today still rely on the use of acrylic-based headposts for stabilization and the use of contrast-enhanced agents to improve MRI signal.

Conclusions: Our method preserves fMRI-compatibility and results in measurable improvement in BOLD signal without the use of contrast-enhanced agents. Furthermore, the long-term stability of our implants contributes positively to the wellbeing of NHPs in neuroscience research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6203806PMC
http://dx.doi.org/10.1016/j.jneumeth.2018.09.013DOI Listing

Publication Analysis

Top Keywords

implants
9
mri-compatible implants
8
nonhuman primates
8
contrast-enhanced agents
8
improved methods
4
methods mri-compatible
4
implants nonhuman
4
primates background
4
background neuroscientists
4
neuroscientists commonly
4

Similar Publications

Individualized total knee arthroplasty achieves better functional results than off-the-shelf implants in patients undergoing personalized coronal alignment.

Knee

January 2025

IULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d'Azur, Nice, France; ICARE Team, Côte d'Azur University, Inserm, CNRS, Valrose Institute of Biology, Nice, France. Electronic address:

Background: Several studies have demonstrated the interest in patient-specific custom cutting guides in total knee arthroplasty (TKA), but clinical improvement remains debated. The purpose of this study was to evaluate the functional outcomes (Forgotten Joint Score, FJS) of patients undergoing individualized TKA compared with those receiving off-the-shelf (OTS) implants, both using patient-specific cutting guides with personalized alignment over a minimum follow up period of 12 months. We hypothesized that individualized TKA demonstrates significantly better functional outcomes than OTS TKA (FJS and percentage of patients reaching the minimum clinically important difference).

View Article and Find Full Text PDF

Clinical Relevance: Although laser refractive surgeries and multifocal intraocular lens implantation are generally avoided in patients with diabetic retinopathy, a substantial proportion of well-glycaemic-controlled type 2 diabetes mellitus patients are considered for these procedures. Pupil dynamics play a significant role in determining postoperative satisfaction in these patients.

Background: To evaluate pupillary dynamics in patients with and without diabetes following uneventful phacoemulsification surgery.

View Article and Find Full Text PDF

Purpose: Vertebral body tethering (VBT) is a non-fusion surgical option for adolescent idiopathic scoliosis (AIS) that requires a postoperative (PO) chest tube. This study evaluates whether 48 h of PO TXA reduces chest tube (CT) drainage and retention compared to 24 h of TXA following VBT for AIS.

Methods: Consecutively treated patients with a diagnosis of AIS who underwent VBT were assessed.

View Article and Find Full Text PDF

Postinfarction ventricular septal rupture (PIVSR) is a rare but serious complication of acute myocardial infarction. Determining how to conduct surgical repair safely is critical. We compared the outcomes of Impella and intra-aortic balloon pump (IABP) implantation during perioperative mechanical circulatory support management in patients with PIVSR (n = 22).

View Article and Find Full Text PDF

Objective: To assess the impact of cochlear implantation (CI) and speech perception outcomes on the quality of life (QoL) of adult CI users and their communication partners (CP) one-year post-implantation.

Design: This research is part of a prospective multicenter study in The Netherlands, called SMILE (Societal Merit of Intervention for hearing Loss Evaluation).

Study Sample: Eighty adult CI users completed speech perception testing and the Nijmegen Cochear Implant Questionnaire (NCIQ).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!