Relationship of Time-Activity-Adjusted Particle Number Concentration with Blood Pressure.

Int J Environ Res Public Health

Department of Civil and Environmental Engineering, Tufts University School of Engineering, 200 College Ave, Medford, MA 02155, USA.

Published: September 2018

Emerging evidence suggests long-term exposure to ultrafine particulate matter (UFP, aerodynamic diameter < 0.1 µm) is associated with adverse cardiovascular outcomes. We investigated whether annual average UFP exposure was associated with measured systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP), and hypertension prevalence among 409 adults participating in the cross-sectional Community Assessment of Freeway Exposure and Health (CAFEH) study. We used measurements of particle number concentration (PNC, a proxy for UFP) obtained from mobile monitoring campaigns in three near-highway and three urban background areas in and near Boston, Massachusetts to develop PNC regression models (20-m spatial and hourly temporal resolution). Individual modeled estimates were adjusted for time spent in different micro-environments (time-activity-adjusted PNC, TAA-PNC). Mean TAA-PNC was 22,000 particles/cm³ (sd = 6500). In linear models (logistic for hypertension) adjusted for the minimally sufficient set of covariates indicated by a directed acyclic graph (DAG), we found positive, non-significant associations between natural log-transformed TAA-PNC and SBP (β = 5.23, 95%CI: -0.68, 11.14 mmHg), PP (β = 4.27, 95%CI: -0.79, 9.32 mmHg), and hypertension (OR = 1.81, 95%CI: 0.94, 3.48), but not DBP (β = 0.96, 95%CI: -2.08, 4.00 mmHg). Associations were stronger among non-Hispanic white participants and among diabetics in analyses stratified by race/ethnicity and, separately, by health status.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6165221PMC
http://dx.doi.org/10.3390/ijerph15092036DOI Listing

Publication Analysis

Top Keywords

blood pressure
12
particle number
8
number concentration
8
relationship time-activity-adjusted
4
time-activity-adjusted particle
4
concentration blood
4
pressure
4
pressure emerging
4
emerging evidence
4
evidence suggests
4

Similar Publications

Ferulic acid (FA) is a phenolic compound obtained naturally and is a versatile antioxidant identified for its potential in managing hypertension. However, its application is constrained due to its classification as a BCS Class IV moiety. To address this, we concentrated on improving its solubility and permeability by developing nanostructured lipid carriers (NLCs) of FA using emulsification probe sonication technique.

View Article and Find Full Text PDF

Background: Non-invasive, continuous blood pressure monitoring technologies require additional validation beyond standard cuff-based methods. This study evaluates a non-invasive, multiparametric wearable cuffless blood pressure (BP) diagnostic monitor across all hypertension classes with diverse subjects.

Methods: A prospective, multicenter study assessed Nanowear's SimpleSense-BP performance, including induced and natural BP changes, significant BP variations (Systolic BP (SBP) ≥ ± 15 mm Hg and Diastolic BP (DBP) ≥ ± 10 mm Hg), and reference input value validity over 4 weeks.

View Article and Find Full Text PDF

Time-varying intensity of ventilatory inefficiency and mortality in patients with acute respiratory distress syndrome.

Ann Intensive Care

January 2025

Jiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, No. 87, Dingjiaqiao Road, Gulou District, Nanjing, 210009, People's Republic of China.

Background: The association between bedside ventilatory parameters-specifically arterial carbon dioxide pressure (PaCO) and ventilatory ratio (VR)-and mortality in patients with acute respiratory distress syndrome (ARDS) remains a topic of debate. Additionally, the persistence of this association over time is unclear. This study aims to investigate the relationship between 28-day mortality in ARDS patients and their longitudinal exposure to ventilatory inefficiency, as reflected by serial measurements of PaCO and VR.

View Article and Find Full Text PDF

Background And Objective: There is no satisfactory treatment for obstructive sleep apnea (OSA) in patients with interstitial lung disease (ILD) because of poor tolerance of positive airway pressure (PAP) therapy. Supplemental oxygen therapy has been shown to reduce hypoxemia and is well tolerated in patients with ILD. However, little is known about the effect of nocturnal oxygen supplementation (NOS) on OSA in patients with ILD.

View Article and Find Full Text PDF

Background: Hyponatremia is one of the complicating findings in acute decompensated heart failure. Decrease in cardiac output and systemic blood pressure triggers activation of renin-angiotensin-aldosterone system, antidiuretic hormone, and norepinephrine due to the perceived hypovolemia. Fluid-overloaded heart failure patients are commonly treated with loop diuretics, acutely decompensated heart failure patients tend to be less responsive to conventional oral doses of a loop diuretic, while other different diuretics could work in different part of nephron circulation system.

View Article and Find Full Text PDF