Purpose: The aim of this study was to analyze and compare the stress distribution patterns of different implant and restorative materials in the supporting tissue and implants.
Materials And Methods: Twelve different implant/bone models were created using SolidWorks 2015 software (SolidWorks Corp) and analyzed using the finite element method. Straumann Bone Level implants with zirconia abutments and single-piece Straumann PURE Ceramic implants (Institute Straumann) restored with lithium disilicate glass-ceramic and zirconia ceramic cement-retained crowns were evaluated. A 118.2-N load was applied to the coronal aspect of the buccal cusp at a 75.8-degree angle in relation to the occlusal plane. Principal stress values for cortical and trabecular bone and the equivalent von Mises stress values for implants and frameworks were calculated.
Results: Zirconia (ZrO) implant models showed lower principal stress values than the commercially pure titanium (cpTi) and titanium-zirconium (TiZr) implant models in cortical bone. All models showed similar principal stress values in trabecular bone. Von Mises stress values at the cpTi and TiZr implants were similar; however, values observed of ZrO implants were higher. TiZr implants of 3.3 mm diameter showed similar strength to 4.1-mm-diameter cpTi implants. Both zirconia and lithium disilicate glass-ceramic frameworks transferred similar von Mises stress values in the supporting tissue of implant-supported prostheses.
Conclusion: Narrow-diameter TiZr implants may be preferred for patients who have insufficient bone volume without bone augmentation procedures due to the material's enhanced biomechanical properties. ZrO implants may be a suitable alternative for esthetic regions. Further clinical studies are recommended to investigate the long-term performance of TiZr and ZrO implants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.6261 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!