A Non-Invasive Material Characterization Framework for Bioprosthetic Heart Valves.

Ann Biomed Eng

The DU Cardiovascular Biomechanics Laboratory, Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA.

Published: January 2019

Computational modeling and simulation has become more common in design and development of bioprosthetic heart valves. To have a reliable computational model, considering accurate mechanical properties of biological soft tissue is one of the most important steps. The goal of this study was to present a non-invasive material characterization framework to determine mechanical propertied of soft tissue employed in bioprosthetic heart valves. Using integrated experimental methods (i.e., digital image correlation measurements and hemodynamic testing in a pulse duplicator system) and numerical methods (i.e., finite element modeling and optimization), three-dimensional anisotropic mechanical properties of leaflets used in two commercially available transcatheter aortic valves (i.e., Edwards SAPIEN 3 and Medtronic CoreValve) were characterized and compared to that of a commonly used and well-examined surgical bioprosthesis (i.e., Carpentier-Edwards PERIMOUNT Magna aortic heart valve). The results of the simulations showed that the highest stress value during one cardiac cycle was at the peak of systole in the three bioprostheses. In addition, in the diastole, the peak of maximum in-plane principal stress was 0.98, 0.96, and 2.95 MPa for the PERIMOUNT Magna, CoreValve, and SAPIEN 3, respectively. Considering leaflet stress distributions, there might be a difference in the long-term durability of different TAV models.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-018-02129-5DOI Listing

Publication Analysis

Top Keywords

bioprosthetic heart
12
heart valves
12
non-invasive material
8
material characterization
8
characterization framework
8
mechanical properties
8
soft tissue
8
perimount magna
8
framework bioprosthetic
4
heart
4

Similar Publications

Objectives: To describe the workflow and value of three-dimensional rotational angiography (3DRA) in percutaneous pulmonary valve implantation (PPVI).

Background: 3DRA offers visualization of the entire topography in the chest and may enhance safety and reduce the risk for complications in PPVI through improved pre-procedural planning and per-procedural guidance.

Methods: All PPVI procedures with the use of 3DRA performed between August 2011 and December 2022 were reviewed.

View Article and Find Full Text PDF

Background: With the rapid expansion of transcatheter aortic valve replacement (TAVR), TAVR valve explantation is also increasing. Nevertheless, previous reports on Lotus Edge valve explantation are limited to only two reports, none of which include intraoperative videos. Therefore, we report the case of an older adult who underwent a 2-year-old Lotus Edge valve explantation, after developing prosthetic valve endocarditis (PVE) and aortic annular abscess, with a strong indication for a TAVR explantation and surgical aortic valve replacement (AVR).

View Article and Find Full Text PDF

Recurrent strokes after transcatheter aortic valve replacement in an elderly patient with severe bicuspid aortic valve stenosis: a case report.

BMC Cardiovasc Disord

December 2024

Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing, 100730, China.

Background: Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high-risk patients with symptomatic severe aortic valve stenosis (AS). Recently, its use has also been extended to low-risk patients, resulting in its increasing utilization in patients with bicuspid aortic valve (BAV). But as a serious post-TAVR complication, ischemic stroke was associated with a nearly 6-fold increased 30-day mortality.

View Article and Find Full Text PDF
Article Synopsis
  • Venereal syphilis, caused by the bacteria Treponema pallidum, can escalate to serious complications like tertiary syphilis, which affects the heart decades after the initial infection.
  • A case study highlights a 46-year-old woman who developed life-threatening cardiac issues, including an ascending aortic aneurysm and severe aortic valve damage, due to untreated late-stage syphilis.
  • She underwent surgery to repair her aorta and replace the damaged valve, receiving antibiotics and intensive care; her recovery was satisfactory with no complications reported three months later.
View Article and Find Full Text PDF

Background: Coronary air embolism (CAE) is a complication that can lead to catastrophic outcomes, including myocardial infarction, stroke, and death. It is reported to occur during cardiac catheterization, within a few hours after cardiac surgery, or as a result of chest trauma. This is a case report of delayed coronary air embolism following cardiac surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!