Purpose: The application of a novel platform for nonfluoroscopic catheter sensor tracking within pre-recorded x-ray loops in the context of catheter ablation of atrial fibrillation (AF) demonstrated significant potential for reduction of fluoroscopy. We sought to provide the first prospective randomized comparison of fluoroscopy needs, procedure times, and complications in AF catheter ablation with or without additional use of nonfluoroscopic catheter visualization (NFCV).

Methods: Patients with AF were randomized into two groups before scheduled radiofrequency ablation: (1) using established mapping systems and fluoroscopy as needed (CONV group) or (2) with additional NFCV (NFCV group). All procedures were performed in the same lab using the same ablation catheter tip technology and the same mapping and ablation strategies. Primary endpoints were radiation time and dose. Secondary endpoints were procedural parameters, complications, and long-term success.

Results: A total of 80 patients (48 male patients, mean age 60 years, 46 patients with paroxysmal AF) were randomized into the two groups. Clinical parameters between both groups were similar. NFCV use reduced mean fluoroscopy time (1.9 vs. 13.2 min, p < 0.001) and mean dose (510 vs. 1549 Gycm, p < 0.001) significantly. Procedural parameters were similar in the two groups. One conservatively treated groin complication occurred (1.3%).

Conclusions: Radiation exposure can be significantly reduced by using the novel NFCV technology in addition to standard AF ablation technologies without negative effects on procedure durations, success rates, or complication rates. With the use of the technology, abandonment of lead protection for EP staff is possible following transseptal puncture.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-018-0446-8DOI Listing

Publication Analysis

Top Keywords

catheter ablation
12
nonfluoroscopic catheter
12
ablation atrial
8
atrial fibrillation
8
prospective randomized
8
randomized comparison
8
randomized groups
8
catheter
7
ablation
5
fibrillation nonfluoroscopic
4

Similar Publications

Background: Catheter ablation improves symptoms and quality of life in atrial fibrillation patients, but its effect on adverse cardiovascular outcomes and mortality remains uncertain. Bayesian analysis of randomized controlled trials offers a deeper understanding of treatment effects beyond conventional p-value thresholds.

Methods: We conducted a post hoc Bayesian reanalysis of CABANA and four similar trials to estimate catheter ablation's effect on cardiovascular and survival outcomes.

View Article and Find Full Text PDF

Endoscopic intraductal radiofrequency ablation (ID-RFA) can curatively treat residual intraductal lesions after endoscopic papillectomy. This study aimed to verify the tissue invasiveness of ID-RFA using a novel RF generator and to explore its appropriate settings in an animal experiment, followed by a small clinical study. Pig liver specimens were ablated using a dedicated RF catheter and two RF generators to investigate structural differences between them and the ablation effects produced under various voltage and power settings.

View Article and Find Full Text PDF

Multimodal data-based longitudinal prognostic model for predicting atrial fibrillation recurrence after catheter ablation in patients with patent foramen ovale and paroxysmal atrial fibrillation.

Eur J Med Res

January 2025

Department of Cardiology, Renmin Hospital of Wuhan University; Institute of Molecular Medicine, Renmin Hospital of Wuhan University; Hubei Key Laboratory of Autonomic Nervous System Modulation; Taikang Center for Life and Medical Sciences, Wuhan University; Cardiac Autonomic Nervous System Research Center of Wuhan University; Hubei Key Laboratory of Cardiology; Cardiovascular Research Institute, Wuhan University, No.238 Jiefang Road, Wuhan, Hubei, 430060, People's Republic of China.

Background: Clinical studies on atrial fibrillation (AF) recurrence after catheter ablation in patients diagnosed with patent foramen ovale (PFO) and paroxysmal AF (PAF) are scarce. Here, we aimed to develop a nomogram model utilizing multimodal data for the risk stratification of AF recurrence following catheter ablation in individuals diagnosed with PFO and new-onset PAF.

Methods: Patients with PFO and PAF who underwent catheter ablation at the Renmin Hospital of Wuhan University from January 2018 to June 2020 were consecutively enrolled.

View Article and Find Full Text PDF

Unlabelled: Pulmonary vein (PV) stenosis is a rare complication following PV isolation (PVI) for atrial fibrillation. Despite the benefit of early intervention, screening is not conducted, emphasizing the importance of maintaining a high index of suspicion. Standardized management approaches are unavailable for this serious complication.

View Article and Find Full Text PDF

Background: Slow activation areas, characterized by decreased conduction velocities in the left atrium, are commonly observed in patients with persistent atrial fibrillation (PeAF). However, it remains unclear whether the ablation of slow activation areas combined with pulmonary vein isolation (PVI) improves clinical outcomes in these patients.

Methods: This single-center retrospective study included patients who underwent catheter ablation for PeAF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!