A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New approach for the determination of ortho-phenylphenol exposure by measurement of sulfate and glucuronide conjugates in urine using liquid chromatography-tandem mass spectrometry. | LitMetric

Ortho-phenylphenol (OPP) has been widely used as a fungicide and preservative. Although low-dose studies have demonstrated its low toxicity in animals and humans, high-dose exposure to this contaminant has toxic effects that range from skin irritation to bladder cancer. Thus far, monitoring of OPP exposure in the general population has been performed by measuring OPP after urine hydrolysis with the β-glucuronidase/arylsulfatase enzyme and sometimes by the use of a mineral acid. We developed a sensitive, accurate, and robust method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) to specifically measure two-phase II OPP metabolites excreted in human urine, OPP sulfate (OPP-S), and OPP glucuronide (OPP-G). Comparative analysis of urine samples from 50 volunteers living in the Quebec City area using a direct method and phosphoric acid hydrolysis method previously developed in our laboratory showed no statistically significant difference (p value for paired t test = 0.701) in OPP concentrations. Moreover, a significant difference showed that underestimation (p value for paired t test = 0.025) occurs when β-glucuronidase/arylsulfatase enzyme deconjugation is used. The LOD achieved by the direct method permits the detection of OPP-S and OPP-G metabolites in urine at the submicrogram per liter level. Graphical abstract ᅟ.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-018-1339-5DOI Listing

Publication Analysis

Top Keywords

liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
β-glucuronidase/arylsulfatase enzyme
8
direct method
8
opp
7
urine
5
approach determination
4
determination ortho-phenylphenol
4
ortho-phenylphenol exposure
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!