A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Survey dataset on the performance of combined process of coagulation and ceramic membrane for the removal of reactive black19. | LitMetric

Survey dataset on the performance of combined process of coagulation and ceramic membrane for the removal of reactive black19.

Data Brief

Department Of Environmental Health Engineering, Faculty of Health and Nutrition, Lorestan University of medical sciences, Khorramabad, Iran.

Published: August 2018

The aim of data article was to evaluate effectiveness of the combined process of coagulation, flocculation and filtration to remove reactive black 19 from solution aqueous. In this data article, alum and ferric chloride were selected as a coagulant for instability of color before ceramic membrane. All experiments were performed in batch conditions. The results showed that more than half of the ceramic membrane is made of silica. The BET surface area of the ceramic membrane was 1.877 m g. The size of RB19, alum, and ferric chloride was 996.2 mm, 1216 mm, and 86.26 mm, respectively. Also, the zeta potential of RB19, alum, and ferric chloride was 20.7 mV, 1.59 mV, and 34.7 mV, respectively. The findings showed that the best pH to remove the RB 19 by alum and ferric chloride was less than 7. With increasing concentrations of alum and chlorine ferric the removal of RB 19 increased. For RB19 concentration of 10 mg l, with increasing time from 5 to 15 min, the removal efficiency for alum and ferric were 61-63% and 82-87%, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6141443PMC
http://dx.doi.org/10.1016/j.dib.2018.06.114DOI Listing

Publication Analysis

Top Keywords

alum ferric
20
ceramic membrane
16
ferric chloride
16
combined process
8
process coagulation
8
data article
8
rb19 alum
8
alum
6
ferric
6
survey dataset
4