Background: This study assessed the contribution of intracorporeal (IC) and extracorporeal clearance (EC) of furosemide in patients with septic acute kidney injury (AKI), and the relationship between plasma concentrations and urine volume.
Methods: Prospective cohort observational study of 15 patients with septic AKI undergoing continuous veno-venous hemodiafiltration (CVVHDF) divided according to urine volume (< 500 ml/12 h, Oliguria group, n = 5; > 500 ml/12 h, Diuresis group, n = 10) during continuous infusion of furosemide (120 mg/12 h) at steady-state condition. Plasma and effluent furosemide concentrations were determined by high-performance liquid chromatography (HPLC)-mass spectrometry every 12 h for 48 h.
Results: Furosemide plasma concentrations and total body clearance (TBC) were 6.14 mg/l and 22.1 ml/min for the Oliguria group, and 2.63 mg/l and 54.4 ml/min for the Diuresis group, respectively (p < 0.05). When urine volume was < 500 ml/24 h, the furosemide plasma concentrations peaked at the potentially toxic value of 13.0 mg/l. Furosemide EC was not relevant for the Diuresis group, but it represented 18% of TBC for the Oliguria group. Furosemide plasma concentrations correlated positively with dose infusion for both groups (r = 0.728 and 0.685, p < 0.05), and negatively with urine volume only for the Diuresis (r = - 0.578, p < 0.01) but not for the Oliguria group (r = - 0.089, p = 0.715).
Conclusions: For patients with urine volume > 500 ml/12 h continuous infusion of furosemide up to 480 mg/24 h leads to increasing urine volume, which can predict furosemide plasma levels within its safety range. When the urine volume is lower, the furosemide plasma levels are increased beyond any further diuretic efficacy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s40620-018-0537-8 | DOI Listing |
Drug Metab Dispos
January 2025
Global Clinical Development, Chiesi Farmaceutici SpA, Parma, Italy.
Tanimilast is an inhaled phosphodiesterase-4 inhibitor currently in phase III clinical development for treating chronic obstructive pulmonary disease and asthma. This trial aimed to characterize the pharmacokinetics, mass balance, and metabolite profiling of tanimilast. Eight healthy male volunteers received a single dose of nonradiolabeled tanimilast via powder inhaler (Chiesi NEXThaler [3200 μg]), followed by a concomitant intravenous infusion of a microtracer ([C]-tanimilast: 18.
View Article and Find Full Text PDFBiomarkers
January 2025
PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland.
Background: Growing evidence indicates that noncombustible products could be a tobacco harm reduction tool for smokers who do not quit. The Tobacco Heating System (THS) emits substantially lower levels of harmful cigarette smoke constituents, and previous randomized clinical studies showed improved levels of biomarkers of potential harm (BoPH) linked to smoking-related disease.
Methods: In this cross-sectional study of healthy participants (n = 982) who (i) smoked cigarettes, (ii) had voluntarily switched from smoking to THS use, or (iii) formerly smoked, blood and urine samples were assayed for nine BoPH.
Anim Reprod Sci
January 2025
Department of Gamete and Embryo Biology, Institute of Animal Reproduction and Food Research, Polish Academy of Science, Olsztyn, Poland.
The quality and quantity of stripped and testicular wild northern pike (Esox lucius) sperm was compared and the effectiveness of short-term storage was assessed. Stripped sperm (SS) was collected using abdominal massage. Next, the fish were decapitated and the testes were removed.
View Article and Find Full Text PDFInt J Surg
January 2025
Department of Anesthesiology, Xiangya Hospital, Central South University, Changsha, Hunan, China.
Background: Acute kidney injury (AKI) is a common postoperative complication, and hypotension may contribute. We therefore tested the primary hypothesis that individualized intraoperative blood pressure regulation reduces postoperative AKI in older surgical patients.
Methods: We enrolled patients ≥60 years old scheduled for elective major abdominal surgery with invasive arterial pressure monitoring.
The high compliance of the urinary bladder during filling is essential for its proper function, enabling it to accommodate significant volumetric increases with minimal rise in transmural pressure. This study aimed to elucidate the physical mechanisms underlying this phenomenon by analyzing the ex vivo filling process in rat from a fully voided state to complete distension, without preconditioning, using three complementary imaging modalities. High-resolution micro-CT at 10.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!