A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Combining non-contrast and dual-energy CT improves diagnosis of early gout. | LitMetric

Combining non-contrast and dual-energy CT improves diagnosis of early gout.

Eur Radiol

Division of Rheumatology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.

Published: March 2019

Objectives: To determine the incremental value of non-contrast CT (NCCT) on dual-energy CT (DECT) in symptomatic first metatarsophalangeal (MTP) joints in early gout.

Methods: One hundred and fifteen painful joints were consecutively enrolled and gout was diagnosed based on the 2015 EULAR/ACR criteria and/or arthrocentesis. Two readers independently evaluated DECT alone and combined NCCT and DECT (NCCT+DECT) based on four semiquantitative scales. Sensitivities and specificities were compared using McNemar's test. AUC was compared.

Results: Of the 115 joints, 72 were defined as an early gout group and 43 as a gout-negative group after exclusion. The sensitivity and specificity for the early gout group on DECT alone were as followed: reader 1 - 52.8% and 100.0% and reader 2 - 51.4% and 100.0%. NCCT+DECT results were as follows: reader 1 - 79.2% and 93.0% and reader 2 - 79.2% and 95.3%. AUC was significantly higher in NCCT+DECT compared to that in DECT alone for the early gout group (0.888 vs. 0.774 for reader 1, p = 0.0004; 0.896 vs. 0.816 for reader 2, p = 0.0142). The false-negative cases on DECT occurred more frequently with the first-onset gout, and tended to be affected by a longer duration of symptoms in the post-hoc analysis.

Conclusion: The combined analysis of NCCT and DECT improves diagnostic capabilities in symptomatic early gout involving the first MTP joint.

Key Points: • MSU crystal depositions in early gout may be seen on non-contrast CT, while still being undetectable by DECT. • Combining non-contrast CT and DECT improves detection of early gout. • False negatives of DECT are more common than previously reported in cases of first-onset gout.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-018-5716-4DOI Listing

Publication Analysis

Top Keywords

early gout
28
gout group
12
gout
10
dect
10
combining non-contrast
8
early
8
ncct dect
8
reader 792%
8
first-onset gout
8
dect improves
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!