Background: Pelvic ring injuries constitute only 2 to 8% of all fractures; however, they occur in 20% of polytrauma patients. High-energy pelvic fractures often result in mechanical instability of the pelvic ring. Successful treatment of unstable pelvic ring fractures remains a challenge for orthopedic surgeons. This study presents a novel internal fixation method for stabilizing unstable anterior pelvic ring fractures using a minimally invasive modified pedicle screw-rod fixation (MPSRF) technique.

Methods: This retrospective study included six patients with unstable pelvic ring injuries who underwent MPSRF, with or without posterior fixation. Intraoperative parameters such as blood loss, operative time, complications, and quality of reduction (Matta criteria) were recorded and evaluated by a blinded reviewer.

Results: In the present clinical series, the mean operative times and mean blood loss for unilateral versus bilateral anterior ring fixations were 176.0 min versus 295.6 min, and 153.3 mL versus 550.0 mL, respectively. No iatrogenic neuropraxia of the lateral femoral cutaneous nerve or femoral nerve palsy occurred. The reduction quality, graded by the Matta criteria, was excellent in five patients and good in one patient.

Conclusions: There were no infections, delayed unions, nonunions, or loss of reductions during the follow-up period. Only one patient suffered from a broken rod at 4 months postoperatively. The modified technique represents a novel, minimally invasive procedure for the treatment of anterior pelvic ring fractures and offers a reliable and effective alternative to currently available surgical techniques.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6142692PMC
http://dx.doi.org/10.1186/s13018-018-0945-4DOI Listing

Publication Analysis

Top Keywords

pelvic ring
28
minimally invasive
12
anterior pelvic
12
ring injuries
12
ring fractures
12
treatment anterior
8
pelvic
8
ring
8
modified pedicle
8
pedicle screw-rod
8

Similar Publications

Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis.

View Article and Find Full Text PDF

Abdominal wall repair in adults with bladder exstrophy is challenging. We present a case of a 46-year-old woman with bladder exstrophy presenting with a large midline incisional hernia associated with a 13-cm hypoplasia of both pubic rami that precluded fixation of any abdominal mesh. A two-stage approach was adopted.

View Article and Find Full Text PDF

Case: A 35-year-old man with morbid obesity sustained an ultra-low velocity (ULV) rotational knee dislocation secondary to a fall from standing. The patient was successfully treated using a subcutaneous knee-spanning internal fixator, the "INFIX" technique, which has previously been described for pelvic ring injuries.

Conclusion: This novel technique maintained the stable reduction of an ULV knee dislocation in a patient with morbid obesity until adequate healing was achieved.

View Article and Find Full Text PDF

Background: It is known that fractures of the pelvic ring and acetabulum in work-related accidents are associated with long periods of incapacity to work, a high rate of reduction in earning capacity (MdE) and high costs for pension/severance pay.

Objective: Investigation of changes in pension claims and costs from 2013 to 2019 after isolated fractures of the pelvic ring and acetabulum in work-related accidents in Germany.

Material And Methods: For all patients from the German Social Accident Insurance (DGUV) registry with isolated fractures of the pelvic ring or acetabulum in work-related accidents, linear trend analyses were carried out among others for the proportion of MdE ≥20%, the proportion of cases receiving pension/severance pay and total costs for pension/severance pay from 2013 to 2019.

View Article and Find Full Text PDF

Migrated intra-uterine device to infra-umbilical skin: a rare case report.

BMC Womens Health

December 2024

Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.

Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!