AI Article Synopsis

  • The study investigates how different performance metrics impact the assessment of tourniquet use during emergency simulations, revealing that user rankings can change significantly based on the metric selected.
  • Analysis of data from 200 tourniquet uses showed that some metrics highlighted different challenges for users, leading to substantial differences in performance outcomes and interpretations.
  • The researchers suggest that tailored training methods based on skill levels, such as using mechanical effectiveness metrics for novices, could improve teaching practices and self-assessment in emergency scenarios.

Article Abstract

Background: Readiness to perform lifesaving interventions during emergencies is based on a person's preparation to proficiently execute the skills required. Graphically plotting the performance of a tourniquet user in simulation has previously aided us in developing our understanding of how the user actually behaves. The purpose of this study was to explore performance assessment and learning curves to better understand how to develop best teaching practices.

Methods: These were retrospective analyses of a convenience sample of data from a prior manikin study of 200 tourniquet uses among 10 users. We sought to generate hypotheses about performance assessments relevant to developing best teaching practices. The focus was on different metrics of user performance.

Results: When one metric was chosen over another, failure counts summed cumulatively over 200 uses differed as much as 12-fold. That difference also indicated that the degree of challenge posed to user performance differed by the metric chosen. When we ranked user performance with one metric and then with another, most (90%; nine of 10) users changed rank: five rose and four fell. Substantial differences in performance outcomes resulted from the difference in metric chosen, which, in turn, changed how the outcome was portrayed and thus interpreted. Hypotheses generated included the following: The usefulness of a specific metric may vary by the user's level of skill from novice to expert; demonstration of the step order in skill performance may suffice for initial training of novices; a mechanical metric of effectiveness, like pulse stoppage, may aid in later training of novices; and training users how to practice on their own and self-assess performance may aid their self-development.

Conclusion: The outcome of the performance assessments varied depending on the choice of metric in this study of simulated use of tourniquets.

Download full-text PDF

Source
http://dx.doi.org/10.55460/QCIU-59MADOI Listing

Publication Analysis

Top Keywords

user performance
12
metric chosen
12
performance
10
metric
8
best teaching
8
performance assessments
8
training novices
8
user
6
metric matters!
4
matters! choose
4

Similar Publications

Evaluating the Real-World Safety of Icosapent Ethyl Versus Omega-3 Polyunsaturated Fatty Acid in Nationwide US Veterans Cohort: Examining Atrial Fibrillation and Bleeding Endpoints.

Clin Drug Investig

January 2025

Department of Medicine, Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Perelman School of Medicine, 423 Guardian Drive, Philadelphia, PA, 19104, USA.

Purpose: The REDUCE-IT randomized trial demonstrated a cardiovascular benefit of icosapent ethyl (IPE) but also raised potential safety signals for atrial fibrillation (AF) and serious bleeding. We aimed to evaluate the real-world safety of IPE versus mixed omega-3 polyunsaturated fatty acid (OM-3) formulations.

Methods: This retrospective active comparator new-user cohort study compared rates of new-onset AF and major bleeding (MB) among adult new users of IPE versus OM-3 in 2020-2024 US Veterans Affairs data.

View Article and Find Full Text PDF

Soil colour is a key indicator of soil health and the associated properties. In agriculture, soil colour provides farmers and advises with a visual guide to interpret soil functions and performance. Munsell colour charts have been used to determine soil colour for many years, but the process is fallible, as it depends on the user's perception.

View Article and Find Full Text PDF

Recent Advancements in Localization Technologies for Wireless Capsule Endoscopy: A Technical Review.

Sensors (Basel)

January 2025

Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC 3800, Australia.

Conventional endoscopy is limited in its ability to examine the small bowel and perform long-term monitoring due to the risk of infection and tissue perforation. Wireless Capsule Endoscopy (WCE) is a painless and non-invasive method of examining the body's internal organs using a small camera that is swallowed like a pill. The existing active locomotion technologies do not have a practical localization system to control the capsule's movement within the body.

View Article and Find Full Text PDF

A parallelized field-programmable gate array (FPGA) architecture is proposed to realize an ultra-fast, compact, and low-cost dual-channel ultra-wideband (UWB) pulsed-radar system. This approach resolves the main shortcoming of current FPGA-based radars, namely their low processing throughput, which leads to a significant loss of data provided by the radar receiver. The architecture is integrated with an in-house UWB pulsed radar operating at a sampling rate of 20 gigasamples per second (GSa/s).

View Article and Find Full Text PDF

In the era of big data, advanced data processing devices and smart sensors greatly benefit us in many areas. As for each individual user, data sharing can be an essential part of the process of data collection and transmission. However, the issue of constant attacks on data privacy arouses huge concerns among the public.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!