The study was aimed to determine possible relations between skeletal morphologic parameters to mandibular angle fractures. Retrospective study of 100 patients suffering from mandibular fractures and treated in the Rambam Health Care Campus between the years 2013 and 2017 was conducted. Predictor variable was facial skeletal morphologic features as derived from the measurements. Outcome variable was mandibular angle fractures. About 42 patients suffered from angle fractures. Gonial angle (131.3° versus 118.1°), condylar neck width (8.3 mm versus 6.8 mm sagittaly and 7.1 mm versus 5.8 mm horizontally), and wisdom tooth prevalence and impaction were positively correlated to the fracture. Ramus height (48.3 mm versus 53.4 mm) was negatively correlated to angle fractures. Many reports in the literature show positive relations between impacted 3rd molars and angle fractures, yet only sporadic reports describe relations between facial fractures and facial features. Our results showed the predictable positive relation between angle fractures and 3rd molar prevalence and impaction. Yet surprisingly, we found unequivocal significant positive correlation between angle fractures to gonial angle and condylar neck width and negative correlation to ramus height. Based on the correlation to the gonial angle and ramal height, it is concluded that enlarged anterior vertical growth is a predictor for angle fractures, as are condylar neck width, and wisdom teeth.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0000000000004730 | DOI Listing |
Sci Rep
January 2025
Department of Orthopaedic, South China Hospital of Shenzhen University, Shenzhen, 518116, Guangdong, China.
Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.
View Article and Find Full Text PDFLangmuir
January 2025
Applied Systems Analysis & Research, Sandia National Laboratories, Albuquerque, New Mexico 87123, United States.
Salt formations have been explored for the permanent isolation of spent nuclear fuel based on their high thermal conductivity, self-healing nature, and low hydraulic permeability to brine flow. Vacancy defect concentrations in salt complicate fracture mechanics not driven by dislocation dynamics and can influence the resulting surface structure. Classical molecular dynamic simulations were used to simulate tensile testing of salt crystals (halite) with vacancy defect concentrations of up to 0.
View Article and Find Full Text PDFMed Biol Eng Comput
January 2025
Department of Pediatric Orthopedics, Xinhua Hospital Affiliated With Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Proximal femoral fractures in children are challenging in clinical treatment due to their unique anatomical and biomechanical characteristics. The distribution and characteristics of fracture lines directly affect the selection of treatment options and prognosis. Pediatric proximal femur fractures exhibit distinctive features, with the distribution and characteristics of the fracture line playing a crucial role in deciding optimal treatment.
View Article and Find Full Text PDFNanotechnology
January 2025
Anhui Agricultural University, Hefei, 230036, P. R. China, Hefei, 230036, CHINA.
Strain sensing fabrics are able to sense the deformation of the outside world, bringing more accurate and real-time monitoring and feedback to users. However, due to the lack of clear sensing mechanism for high sensitivity and high linearity carbon matrix composites, the preparation of high performance strain sensing fabric weaving is still a major challenge. Here, an elastic polyurethane(PU)-based conductive fabric(GCPU) with high sensitivity, high linearity and good hydrophobicity is prepared by a novel synergistic conductive network strategy.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Cerrahpasa Faculty of Medicine, Department of Orthopaedics and Traumatology, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Background: The standard approach for addressing intra-articular calcaneal fractures involves open reduction with plate and screw fixation, with ongoing discourse regarding the application of grafts to address bone gaps. The aim of this study is the temporal comparison of the radiological and functional outcomes in patients undergoing surgery for intra-articular calcaneal fractures, with a specific focus on the use of bone grafts.
Methods: Thirty patients, comprising 13 with iliac grafts and 17 without, were enrolled in the study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!