Background: The subscapular system is a versatile vascular network that can provide multiple flaps for reconstruction of the head and neck. A significant drawback of using the subscapular system is that patient positioning can preclude the use of simultaneous two-team ablative and reconstructive surgery. Herein, we describe a novel use of an upper extremity limb positioner (Spider Limb Positioner) used primarily in orthopedic surgery to facilitate concurrent two-team technique in head and neck surgery.
Methods: Using a bean bag and the Spider Limb Positioner for the upper extremity, a semidecubitus position was used for subscapular donor site dissection. Ablative and reconstructive teams worked concurrently in all cases.
Results: This technique was utilized 78 times on 73 patients, with chimeric flaps used in 38% of cases. The average operative time was 466 min. Only one patient required repositioning intraoperatively due to a change in the subscapular donor site side. There were no nerve compression injuries or positioning related complications.
Conclusion: Scapular and parascapular free flaps are useful tools for reconstruction of the head and neck. In a two-team approach, the use of a semidecubitus position in conjunction with the Spider Limb Positioner facilitates exposure for the reconstructive team without compromising access for the ablative team.