Purpose: The purpose of the study is to determine the effectiveness of semi-active and active robotic hip and knee arthroplasty on post-operative patient-reported outcomes of function, pain, quality of life and satisfaction with surgery.

Methods: PubMed, Medline, Embase and CENTRAL were searched. Included were comparative studies investigating the effectiveness of semi-active or active robotic hip or knee arthroplasty compared to any other surgical intervention on function, pain, quality of life and satisfaction with surgery. Risk of bias and the strength of the evidence were assessed using the Downs and Black tool and the GRADE system, respectively. Relative risks, mean differences and 95% CI were calculated using random-effects models.

Results: Fourteen studies involving 1342 patients were included. All studies compared robotic to conventional surgery, with active robotic surgery evaluated in total hip or knee arthroplasty and semi-active robotic surgery in total hip or unicompartmental knee arthroplasty. Most studies presented some risk of bias, and the strength of evidence was rated as low to very low quality. Random-effects meta-analyses showed that post-operative functional outcomes were comparable between active robotic and conventional total hip and knee arthroplasty at the short-, medium- and long-term follow-up. No significant difference in pain, quality of life and satisfaction with surgery were reported in individual studies.

Conclusions: This systematic and meta-analyses indicates that functional outcomes for patients undergoing active robotic total hip and knee arthroplasty were comparable to conventional surgery. Whether semi-active or active robotic hip or knee arthroplasty is effective in improving post-operative pain, quality of life and satisfaction with surgery is unclear. PROSPERO Registration Number: CRD42017059932.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-018-4140-3DOI Listing

Publication Analysis

Top Keywords

knee arthroplasty
32
hip knee
28
active robotic
24
robotic hip
16
pain quality
16
quality life
16
life satisfaction
16
total hip
16
semi-active active
12
satisfaction surgery
12

Similar Publications

[What should be considered in the case of previous operations or injections prior to hip and knee replacement?].

Orthopadie (Heidelb)

January 2025

Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Freiburg, Medizinische Fakultät, Albert-Ludwigs-Universität Freiburg, Freiburg, Deutschland.

Background: Patients who have had prior injections, surgeries such as arthroscopies, and have existing osteosynthetic implants in the hip and knee have an increased risk of periprosthetic infections when undergoing hip (THA) or total knee arthroplasty (TKA).

Osteosynthesis: For patients with osteosynthetic implants in the knee joint, a two-stage procedure (implant removal followed by TKA) is recommended based on the available literature and the high colonization rates. A two-stage procedure is also recommended for patients with hip implants.

View Article and Find Full Text PDF

Stromal vascular fraction (SVF) is a heterogeneous collection of cells obtained from adipose tissue through lipoaspiration and is an alter-native intraarticular treatment option, especially in osteoarthritis (OA). The anti-inflammatory and extracellular tissue repair-stimulating properties of SVF increase its effectiveness in regeneration and repair mechanisms. One of the most common symptoms of hemophilia A and B is hemophilic arthropathy (HA).

View Article and Find Full Text PDF

Inferior outcome of stand-alone short versus long tibial stem in revision total knee arthroplasty. A retrospective comparative study with minimum 2 year follow-up.

SICOT J

January 2025

Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, 69004 Lyon, France - Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622 Lyon, France.

Introduction: Revision Total Knee Arthroplasty (RTKA) is complex, and induced bone loss might endanger implant fixation and joint stability. Intramedullary stems improve fixation throughout stress redistribution. The current study aims to compare the performance of short tibial stems with long tibial stems, investigating their intermediate-term radiographic and survival outcomes in RTKA.

View Article and Find Full Text PDF

Background: Reducing unnecessary emergency department (ED) visits following joint arthroplasty is an important goal. Literature suggests 30-day visit rates range between 4% and 15%, with only 20%-25% of these admitted for care. Low admissions suggest an opportunity to reduce unnecessary postarthroplasty ED visits.

View Article and Find Full Text PDF

Purpose: The purpose of this investigation is to assess and contrast the effectiveness of the two EuroQol five dimensions questionnaire (EQ-5D) versions-EQ-5D-3L and EQ-5D-5L-in assessing one-year quality of life outcomes for patients with knee osteoarthritis (KOA) undergoing unicompartmental knee arthroplasty (UKA).

Material And Method: From the medical records at the Honghui Hospital, Xi'an Jiaotong University, 402 individuals aged 50 and above, who were one-year post-operation, were selected to fill out survey questionnaires during their return hospital visits. Of these, 231 respondents (57.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!