A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner. | LitMetric

Aims: To evaluate image quality, interpretability, diagnostic accuracy and radiation exposure of coronary CT angiography (CCTA) performed with a new scanner equipped with 0.23-mm spatial resolution, new generation iterative reconstruction, 0.28-second gantry rotation time and intra-cycle motion-correction algorithm in consecutive patients with coronary stents, including those with high heart rate (HR) and atrial fibrillation (AF).

Materials And Methods: We enrolled 100 consecutive patients (85 males, mean age 65 ± 10 years) with previous coronary stent implantation scheduled for clinically indicated non-emergent invasive coronary angiography (ICA). Image quality, coronary interpretability and diagnostic accuracy vs. ICA were evaluated and the effective dose (ED) was recorded.

Results: Mean HR during the scan was 67 ± 13 bpm. Twenty-six patients had >65 bpm HR during scanning and 13 patients had AF. Overall, image quality was high (Likert = 3.2 ± 0.9). Stent interpretability was 95.8% (184/192 stents). Among 192 stented segments, CCTA correctly identified 22 out of 24 with >50% in-stent restenosis (ISR) (sensitivity 92%). In a stent-based analysis, specificity, positive and negative predictive values and diagnostic accuracy for ISR detection were 91%, 99%, 60% and 91%, respectively. In a patient-based analysis, CCTA diagnostic accuracy was 85%. Overall, mean ED of CCTA was 2.4 ± 1.2 mSv.

Conclusions: A whole-organ CT scanner was able to evaluate coronary stents with good diagnostic performance and low radiation exposure, also in presence of unfavorable HR and heart rhythm.

Translational Aspect: The present study is the first to evaluate the CCTA capability of detecting in-stent restenosis in consecutive patients, including those with high HR and AF, using a recent scanner generation that combines improved spatial and temporal resolution with wide coverage. Using the whole-organ high-definition CT scanner we obtained high quality images of coronary stents with good interpretability and diagnostic accuracy combined with low radiation exposure, even in patients with unfavorable HR or heart rhythm for CCTA evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2018.09.010DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
24
consecutive patients
16
coronary stents
16
coronary angiography
12
image quality
12
interpretability diagnostic
12
radiation exposure
12
coronary
9
100 consecutive
8
patients coronary
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!