Introduction: A difference of ≥ 50-55 mg/dL between bedtime and morning glucose (BeAM) values in patients with type 2 diabetes (T2D) on basal insulin is an indicator of poor postprandial glucose control. This analysis compared the effect of treatment with a fixed-ratio combination of insulin glargine/lixisenatide (iGlarLixi) vs insulin glargine (iGlar) on BeAM values, and evaluated the impact of BeAM values on glycemic and safety endpoints.

Methods: In this post hoc analysis of 517 participants from the LixiLan-L trial, change in BeAM values and composite efficacy and safety endpoints stratified by BeAM value < 55 mg/dL or ≥ 55 mg/dL were evaluated in patients with T2D uncontrolled on basal insulin randomized to iGlarLixi or iGlar over 30 weeks (LixiLan-L).

Results: Greater reductions in BeAM values were seen with iGlarLixi vs iGlar, and a higher proportion of patients reached a BeAM value < 55 mg/dL in the iGlarLixi arm. A BeAM value < 55 mg/dL was associated with improved glycemic control, lower risk of hypoglycemia, and a greater proportion of patients achieving glycemic targets without hypoglycemia or weight gain. Greater reductions in BeAM values were seen with iGlarLixi vs iGlar, irrespective of stratification by glycated hemoglobin A or glycemic endpoints.

Conclusions: Greater reductions in bedtime-to-morning glucose differential, or BeAM, were observed with iGlarLixi vs iGlar in patients with T2D uncontrolled on basal insulin, reflecting better overall control of both fasting and prandial glucose and more appropriate matching of therapy to physiologic needs.

Trial Registration: ClinicalTrials.gov Identifier NCT02058160.

Funding: Sanofi US, Inc.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6167304PMC
http://dx.doi.org/10.1007/s13300-018-0507-0DOI Listing

Publication Analysis

Top Keywords

beam values
16
type diabetes
8
post hoc
8
hoc analysis
8
beam
5
bedtime-to-morning glucose
4
glucose difference
4
difference iglarlixi
4
iglarlixi type
4
diabetes post
4

Similar Publications

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

Aim: The aim of this cross-sectional prospective study was to evaluate the bone density changes around the bicortical corticobasal implant placed in the maxilla over 18 months of follow-up using cone-beam computed tomography (CBCT), focusing on the comparison between the anterior and posterior teeth and regions.

Materials And Methods: Thirty-five subjects (20, 53.26%, were males, and 15, 46.

View Article and Find Full Text PDF

Although the modulus of elasticity of the human periodontal ligament (E) values used in dentistry widely ranged from 0.01 to 175 MPa, the exact E value has not been determined. This study aimed to verify whether and how E values affect the stress distribution over the tooth and periodontium structures, and to determine the appropriate E range.

View Article and Find Full Text PDF

This paper examines the circumstances under which a one-degree-of-freedom approximate system can be employed to predict the dynamics of a cantilever beam comprising an elastic element with a significant mass and a concentrated mass embedded at its end, impacting a moving rigid base. A reference model of the system was constructed using the finite element method, and an approximate lowest-order model was proposed that could be useful in engineering practice for rapidly ascertaining the dynamics of the system, particularly for predicting both periodic and chaotic motions. The number of finite elements in the reference model was determined based on the calculated values of natural frequencies, which were found to correspond to the values of natural frequencies derived from the application of analytical formulas.

View Article and Find Full Text PDF

Frequency-domain thermoreflectance with beam offset without the spot distortion for accurate thermal conductivity measurement of anisotropic materials.

Rev Sci Instrum

January 2025

Department of Micro Engineering, Graduate School of Engineering, Kyoto University, Kyotodaigaku-Katsura C3, Nishikyo-ku, Kyoto 615-8540, Japan.

The measurement of thermal conductivities of anisotropic materials and atomically thin films is pivotal for the thermal design of next-generation electronic devices. Frequency-domain thermoreflectance (FDTR) is a pump-probe technique that is known for its accurate and straightforward approach to determining thermal conductivity and stands out as one of the most effective methodologies. Existing research has focused on advancing a measurement system that incorporates beam-offset FDTR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!