A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

pH-Based Detection of Target Analytes in Diluted Serum Samples Using Surface Plasmon Resonance Immunosensor. | LitMetric

pH-Based Detection of Target Analytes in Diluted Serum Samples Using Surface Plasmon Resonance Immunosensor.

Appl Biochem Biotechnol

Department of Chemical Engineering, Kanpur, India.

Published: April 2019

Detection of minute quantities of target antigens in serum samples (consisting of a mixture of proteins/biomolecules) can be achieved by enhancement of the capture efficiencies of heterogeneous immunosensors. An important process parameter which affects the capture of target analytes in such immunosensors is the pH of the solution as the target proteins present in the serum samples are charged molecules. Here, we investigated the capture of prostate-specific antigens (PSAs), first in a mixed-analyte system wherein the solution contained two other non-specific proteins along with the target analyte, using the surface plasmon resonance spectroscopy. There are no reports on the detection of antigens in a mixed system based on the optimization of the pH values of the carrier fluid, and this is the motivation of the present work. Further, we studied interference effects caused by the presence of these non-specific proteins in the mixed-analyte systems by artificially increasing the ratio of the interfering proteins to that of the target protein. Eventually PSA spiked into the rabbit serum samples was captured through the optimization of the pH of the solution. We could detect PSA in the serum samples when diluted to 100 times or more, where the amounts of other interfering proteins were ~ 66 times that of the amount of PSA. This study proposes a heterogeneous immunosensor to detect the target analytes in the diluted serum samples by tuning pH the of solution mixture, which can be utilized to detect disease biomarkers in serum samples.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12010-018-2883-3DOI Listing

Publication Analysis

Top Keywords

serum samples
28
target analytes
12
analytes diluted
8
diluted serum
8
surface plasmon
8
plasmon resonance
8
non-specific proteins
8
proteins target
8
interfering proteins
8
target
7