The purpose of this work is to assess eight detectors performance for output factor (OF), percent depth dose (PDD), and beam profiles in a 6-MV Clinac stereotactic radiosurgery mode for cone irradiation using Monte Carlo simulation as reference. Cones with diameters comprised between 30 and 4 mm have been studied. The evaluated detectors were ionization chambers: pinpoint and pinpoint 3D, diodes: SRS, P and E, Edge, MicroDiamond and EBT3 radiochromic films. The results showed that pinpoints underestimate OF up to -2.3% for cone diameters ≥10 mm and down to -12% for smaller cones. Both nonshielded (SRS and E) and shielded diodes (P and Edge) overestimate the OF respectively up to 3.3% and 5.2% for cone diameters ≥10 mm and in both cases more than 7% for smaller cones. MicroDiamond slightly overestimates the OF, 3.7% for all the cones and EBT3 film is the closest to Monte Carlo with maximum difference of ±1% whatever the cone size is. For the profiles and the PDD, particularly for the small cones, the size of the detector predominates. All diodes and EBT3 agree with the simulation within ±0.2 mm for beam profiles determination. For PDD curve all the active detectors response agree with simulation up to 1% for all the cones. EBT3 is the more accurate detector for beam profiles and OF determinations of stereotactic cones but it is restrictive to use. Due to respectively inappropriate size of the sensitive volume and composition, pinpoints and diodes do not seem appropriate without OF corrective factors below 10 mm diameter cone. MicroDiamond appears to be the best detector for OF determination regardless all cones. For off-axis measurements, the size of the detector predominates and for PDD all detectors give promising results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6236831PMC
http://dx.doi.org/10.1002/acm2.12449DOI Listing

Publication Analysis

Top Keywords

beam profiles
12
cones
9
stereotactic radiosurgery
8
monte carlo
8
cone diameters
8
diameters ≥10 mm
8
smaller cones
8
cones ebt3
8
size detector
8
detector predominates
8

Similar Publications

Purpose: Minibeam radiotherapy (MBRT) uses small parallel beams of radiation to create a highly modulated dose pattern. The aim of this study is to develop an optical radioluminescence imaging (RLI) approach to perform real-time dose measurement for MBRT.

Methods: MBRT was delivered using an image-guided small animal irradiator equipped with a custom collimator.

View Article and Find Full Text PDF

Median mandibular cyst is defined as an odontogenic cyst in a rare midline location. In spite of this definition, there have been two reports of a peculiar lesion, so-called "ciliated" median mandibular cyst associated with vital teeth, the origin of which cannot be explained in terms of odontogenic epithelium multipotentiality. We describe a thorough profile of an additional example.

View Article and Find Full Text PDF

Ion beam mutagenesis is an advanced technique capable of inducing substantial changes in plants, resulting in noticeable alterations in their growth. However, the precise molecular mechanisms underlying the effects of radiation on soybeans remain unclear. This study investigates the impact of ionizing radiation on soybean development through a comprehensive approach that integrates transcriptomics and metabolomics.

View Article and Find Full Text PDF

Introduction: Cutaneous T-cell lymphoma (CTCL) is closely associated with the host microbiome. While recent evidence suggests that shifts in specific bacterial taxa are associated with response to UV-B, a form of non-ionizing radiation, the impact of ionizing radiation (IR) has not been investigated.

Methods: 16S rRNA and gene amplicon sequencing were performed on DNA extracted from swabs of lesional/non-lesional skin of 12 CTCL patients before/after TSEBT or local IR and from 25 matched healthy controls (HC).

View Article and Find Full Text PDF

The article provides information about strengthening cold-formed thin-walled steel beams made of the sigma profile. An innovative concept for sectional transverse strengthening of thin-walled beams subjected to concentrated forces was investigated. The proposed solution's novelty lies in attaching the sectional transverse strengthening to the beam's cross-section, employing a point crimping technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!