Introduction During the last 20 years, there has been a considerable increase in the number of implanted implantable cardioverter‑defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices. However, there have been only single reports on clinical events, including rehospitalizations, in the long‑term follow‑up. Objectives We analyzed the baseline clinical characteristics, medical procedures used, and complications of patients with implantation of an ICD or CRT device. Moreover, we analyzed the causes of rehospitalization and the types of treatment used in the 12‑month follow‑up. Patients and methods Out of 1 208 440 hospitalizations of patients with cardiovascular diseases included in the SILCARD registry, hospitalizations with an ICD‑9 code for an ICD or CRT device implantation between 2006 and 2016 were selected. Results The analysis included 12 147 patients with an ICD or CRT device. The total number of hospitalizations was 14 552. Over the years, a significant increase in the number of implanted devices and a higher percentage of CRT defibrillators was observed. Before the implantation, approximately 48.2% of patients underwent revascularization. In‑hospital and 12‑month mortality rates were 0.4% and 8.1%, respectively. Rehospitalizations due to cardiovascular causes were reported for approximately 40.3% of patients, with a significant reduction in the analyzed period. The most frequent cause of rehospitalization was heart failure (51.4%), while stable coronary artery disease and acute coronary syndromes constituted approximately 16% of the causes. In the 12‑month follow‑up, nearly every tenth patient was subjected to coronary angiography. Approximately 5% of patients required revascularization. Conclusions The relatively high rates of hospital readmissions and their causes indicate the need for a comprehensive care of patients before implantation of ICD or CRT devices and after discharge.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.20452/pamw.4332 | DOI Listing |
Strahlenther Onkol
January 2025
TUM School of Medicine and Health, Department of Radiation Oncology, Technische Universität München (TUM), Klinikum rechts der Isar, Munich, Germany.
Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.
View Article and Find Full Text PDFJ Clin Med
December 2024
University Hospital of Grenoble Alpes, INSERM U1300, 38043 Grenoble, France.
Cardiac implantable electronic devices and their integrated thoracic impedance sensors have been used to detect sleep apnea for over a decade now. Despite their usage in daily clinical practice, there are only limited data on their diagnostic accuracy. AIRLESS and UPGRADE were prospective investigator-driven trials meant to validate the AP scan (Boston Scientific, Marlborough, MA, USA) in heart failure cohorts.
View Article and Find Full Text PDFBAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.
View Article and Find Full Text PDFTurk J Med Sci
December 2024
Deputy Health Minister, Ministry of Health, Ankara, Turkiye.
Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.
View Article and Find Full Text PDFPLoS One
December 2024
Division of Cardiology, Department of Medicine, Karolinska Institutet, Stockholm, Sweden.
Aim: The association of cardiac implantable electronic devices (CIED), namely pacemaker (PM), implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy with (CRT-D) or without defibrillator (CRT-P) with health-related quality of life (HRQoL) is lacking.
Methods And Results: Data from the Swedish Pacemaker and ICD Registry collected from January 2019 to February 2022 was used to analyze the responses to the European Quality of Life-5 Dimension questionnaire (EQ-5D) before and after one year of the CIED implant. Descriptive analysis was performed using Pearson's chi-square test, the analysis of variance ANOVA, the Kruskal-Wallis test and Wilcoxon signed-rank test when appropriate.