Collision cross section (CCS, Ω) values determined by ion mobility mass spectrometry (IM-MS) provide the study of ion shape in the gas phase and use of these as further identification criteria in analytical approaches. Databases of CCS values for a variety of molecules determined by different instrument types are available. In this study, the comparability of CCS values determined by a drift tube ion mobility mass spectrometer (DTIM-MS) and a traveling wave ion mobility mass spectrometer (TWIM-MS) was investigated to test if a common database could be used across IM techniques. A total of 124 substances were measured with both systems and CCS values of [M + H] and [M + Na] adducts were compared. Deviations <1% were found for most substances, but some compounds show deviations up to 6.2%, which indicate that CCS databases cannot be used without care independently from the instrument type. Additionally, it was found that for several molecules [2M + Na] ions were formed during electrospray ionization, whereas a part of them disintegrates to [M + Na] ions after passing through the drift tube and before reaching the TOF region, resulting in two signals in their drift spectrum for the [M + Na] adduct. Finally, the impact of different LC-IM-MS settings (solvent composition, solvent flow rate, desolvation temperature, and desolvation gas flow rate) were investigated to test whether they have an influence on the CCS values or not. The results showed that these conditions have no significant impact. Only for karbutilate changes in the drift spectrum could be observed with different solvent types and flow rates using the DTIM-MS system, which could be caused by the protonation at different sites in the molecule.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.8b02711DOI Listing

Publication Analysis

Top Keywords

ccs values
20
ion mobility
20
mobility mass
20
values determined
12
mass spectrometry
12
traveling wave
8
wave ion
8
drift tube
8
tube ion
8
mass spectrometer
8

Similar Publications

Background: The majority of functional ischemia tests in patients with suspected chronic coronary syndromes (CCS) yield normal results. Implementing gatekeepers for patient preselection, such as pretest probability (PTP) and/or coronary artery calcium score (CACS), could reduce the number of normal scan results, radiation exposure and costs. However, the efficacy and safety of these approaches remain unclear.

View Article and Find Full Text PDF

Fractional flow reserve (FFR) and index of microcirculatory resistance (IMR) relationship in patients with chronic or stabilized acute coronary syndromes.

Int J Cardiol

January 2025

Center of Excellence in Cardiovascular Sciences, Ospedale Isola Tiberina, Gemelli Isola, Via di Ponte Quattro Capi, 39, 00186 Rome, Italy; Department of Cardiovascular and Pneumological Sciences, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli, 8, 00168 Rome, Italy. Electronic address:

Aims: To investigate the influence of index of microcirculatory resistance (IMR) on fractional flow reserve (FFR) and adenosine-induced hyperemia (ΔPd/Pa-FFR) in patients with chronic (CCS) or stabilized acute coronary syndromes (ACS), utilizing various IMR threshold values.

Methods: Data were extracted from two ongoing Italian registries involving patients with CCS or stabilized ACS who underwent a #FullPhysiology approach [Pd/Pa, FFR, IMR, coronary flow reserve (CFR)] by bolus thermodilution technique in the left anterior descending artery. Correlations between IMR and both FFR and ΔPd/Pa-FFR were analyzed both globally and within three IMR-defined groups: Group 1 (IMR <25), Group 2 (25 ≤ IMR <40), and Group 3 (IMR ≥40).

View Article and Find Full Text PDF

Improving Understanding of Fexofenadine Pharmacokinetics to Assess Pgp Phenotypic Activity in Older Adult Patients Using Population Pharmacokinetic Modeling.

Clin Pharmacokinet

January 2025

Clinical Pharmacology and Toxicology Service, Anesthesiology, Pharmacology and Intensive Care Department, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1205, Geneva, Switzerland.

Background And Objective: Fexofenadine is commonly used as a probe substrate to assess P-glycoprotein (Pgp) activity. While its use in healthy volunteers is well documented, data in older adult and polymorbid patients are lacking. Age- and disease-related physiological changes are expected to affect the pharmacokinetics of fexofenadine.

View Article and Find Full Text PDF

: Implementing self-sampling (SS) in cervical cancer screening requires comparable results to clinician-collected samples (CCS). Agreement measures are essential for evaluating HPV test performance. Previous studies on non-paired samples have reported higher viral cycle threshold (Ct) values in SS compared to CCS, affecting sensitivity for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+).

View Article and Find Full Text PDF

On 12 January 2024, Cabo Verde was officially certified by the WHO as a malaria-free country after six consecutive years without local transmission. This study analysed the malaria history of Cabo Verde from 1953 to certification in 2024, highlighted the valuable lessons learned, and discussed challenges for prevention reintroduction. Malaria data from the last 35 years (1988-2022) were analysed using descriptive analyses, and cases were mapped using the USGS National Map Viewer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!