The limiting antigen (LAg)-avidity assay is a serologic assay used for cross-sectional HIV incidence testing. We compared the results obtained with the LAg-avidity assay using dried blood spot (DBS) samples stored at room temperature (18°C-25°C) or stored frozen at -80°C with results obtained from matched plasma samples. Matched DBS and plasma samples (306 paired samples) were collected in the HIV Prevention Trials Network (HPTN) 068 trial in South Africa (2012-2014). The DBS were stored at room temperature before testing. Matched DBS and plasma samples (100 paired samples) from the Consortium for the Evaluation and Performance of HIV Incidence Assays (CEPHIA) were collected in 2016 and were stored at -80°C. All DBS testing was performed in 2017. Differences in normalized optical density (ODn) were compared between matched DBS and plasma samples. For DBS samples stored at room temperature (HPTN 068), the average difference in ODn values for plasma versus DBS was 1.49 (95% confidence intervals [CI]: 1.36-1.62). In contrast, when DBS samples were stored at -80°C (CEPHIA), the average difference in ODn values for plasma versus DBS was -0.22 (95% CI: -0.32 to -0.13). DBS samples stored at room temperature should not be used for cross-sectional HIV incidence testing with the LAg-avidity assay.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6306669PMC
http://dx.doi.org/10.1089/AID.2018.0138DOI Listing

Publication Analysis

Top Keywords

stored room
20
room temperature
20
hiv incidence
16
dbs samples
16
samples stored
16
plasma samples
16
incidence testing
12
lag-avidity assay
12
matched dbs
12
dbs plasma
12

Similar Publications

Background: Inhalational anesthetic agents are a major source of potent greenhouse gases in the medical sector, and reducing their emissions is a readily addressable goal. Nitrous oxide (NO) has a long environmental half-life relative to carbon dioxide combined with a low clinical potency, leading to relatively large amounts of NO being stored in cryogenic tanks and H cylinders for use, increasing the chance of pollution through leaks. Building on previous findings, Stanford Health Care's (SHC's) NO emissions were analyzed at 2 campuses and targeted for waste reduction as a precursor to system-wide reductions.

View Article and Find Full Text PDF

Globally there is a shortage of available donor corneas with only 1 cornea available for every 70 needed. A large limitation to corneal transplant surgery is access to quality donor tissue due to inadequate eye donation services and infrastructure in many countries, compounded by the fact that there are few available long-term storage solutions for effectively preserving spare donor corneas collected in countries with a surplus. In this study, we describe a novel technology termed low-temperature vacuum evaporation (LTVE) that can effectively dry-preserve surplus donor corneal tissue, allowing it to be stored for approximately 5 years, shipped at room temperature, and stored on hospital shelves before rehydration prior to ophthalmic surgery.

View Article and Find Full Text PDF

Co-encapsulation of Creatininase, Creatinase, and Sarcosine Oxidase in Yeast Spore for Creatinine Degradation.

Appl Biochem Biotechnol

January 2025

School of Life Science and Bioengineering, Jining University, 1 Xingtan Road, Qufu, 273155, Shangdong, China.

Creatinine clearance is used to reflect the glomerular filtration rate to assess kidney function. Creatinine degradation-related enzymes have been used for creatinine detection in clinical medicine. The mixture of spores encapsulating either creatininase or creatinase or sarcosine oxidase could mediate a three-step reaction to produce hydrogen peroxide from creatinine.

View Article and Find Full Text PDF

One of the key surveillance strategies for the early detection of an African swine fever (ASF) incursion into a country is the sampling of wild or feral pig populations. In Australia, the remote northern regions are considered a risk pathway for ASF incursion due to the combination of high numbers of feral pigs and their close proximity to countries where ASF is present. These regions primarily consist of isolated arid rangelands with high average environmental temperatures.

View Article and Find Full Text PDF

Impact of Sample Storage Time and Temperature on the Stability of Respiratory Viruses and Enteric Viruses in Wastewater.

Microorganisms

November 2024

Public Health Laboratory, Alberta Precision Laboratories, Edmonton, AB T6G 2J2, Canada.

Wastewater-based surveillance (WBS) has been widely used to track SARS-CoV-2 as well as many other viruses in communities during the COVID pandemic and post-pandemic. However, it is still not clear how temperature and storage time would influence the stability of viruses in wastewater. In this study, we assessed the stability of SARS-CoV-2, pepper mild mottle virus (PMMoV), influenza viruses A (IAV) and B (IBV), respiratory syncytial virus (RSV), and enteric viruses in raw wastewater stored at room temperature, 4 °C, and -20 °C for 3 and 6 days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!