The Watchman device is a transcatheter left atrial appendage (LAA) occluding device used in patients with nonvalvular atrial fibrillation (NVAF) and a high CHADS2-VA2SC score who are poor long-term anticoagulation candidates. Pericardial effusion related to device deployment and perforation can be a life-threatening complication. While not common in hands of experienced operators, management may require surgical intervention. Here we present a rare case of LAA perforation, which was corrected by successful repositioning of the device foregoing the need for surgical management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6134491PMC
http://dx.doi.org/10.1177/2324709618800108DOI Listing

Publication Analysis

Top Keywords

left atrial
8
atrial appendage
8
device deployment
8
device
5
appendage occlusion
4
occlusion complicated
4
complicated appendage
4
appendage perforation
4
perforation rescued
4
rescued device
4

Similar Publications

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.

View Article and Find Full Text PDF

Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.

Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.

View Article and Find Full Text PDF

Objective: To explore the risk factors associated with postoperative atrial fibrillation (POAF) after off-pump coronary artery bypass grafting (OPCABG) and to construct a nomogram predictive model.

Methods: In this retrospective cohort study, clinical data of 193 patients who received OPCABG in Huai'an First People's Hospital Affiliated to Nanjing Medical University from June 2021 to November 2023 were retrospectively analyzed. Based on the established diagnosis of POAF, patients were divided into the POAF group (n=75) and the non-POAF group (n=118).

View Article and Find Full Text PDF

Background: Up to 50% of patients undergoing mitral transcatheter edge-to-edge repair (MTEER) have an indication for left atrial appendage occlusion (LAAO). However, prospective evaluation of this strategy is lacking.

Objectives: The aim of the study was to prospectively evaluate the outcomes of combined LAAO and MTEER.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!